Toshiba e-STUDIO163 Service Handbook page 33

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO163:

Advertisement

Notes:
The digit after the hyphen in "Code" of the following table is a sub code.
In "RAM", the NVRAM of the board in which the data of each code is stored is indicated. "M"
stands for the MAIN board.
Classi-
Code
fication
200
Devel-
Automatic adjustment of
oper
auto-toner sensor
(Fuser heater ON)
201
Devel-
Correction of auto-toner
oper
sensor
(Fuser heater ON)
205
Devel-
Developer bias DC output
oper
adjustment
210
Charger Main charger grid bias out-
put adjustment
220
Transfer Transfer transformer DC
output adjustment (H)
221
Transfer Transfer transformer DC
output adjustment (C)
222
Transfer Transfer transformer DC
output adjustment (L)
233
Separa-
Separation transformer DC
tion
output adjustment (H)
234
Separa-
Separation transformer DC
tion
output adjustment (C)
235
Separa-
Separation transformer DC
tion
output adjustment (L)
247
Devel-
Relative humidity latest
oper
value
248
Devel-
Drum temperature latest
oper
value
270
Devel-
Temperature latest value
oper
280
Process Forced performing of idling
for toner recycle
286
Laser
Laser power adjustment
December 2005 © TOSHIBA TEC
Adjustment mode (05)
Default
Func-
<Accept-
Items
tion
ALL
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-255>
ALL
<0-100>
ALL
<0-100>
ALL
<0-50>
ALL
ALL
<0-255>
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 15
RAM
Contents
able
value>
-
-
As the value increases,
the sensor output
increases correspond-
ingly.
The value starts chang-
ing approx. 2 minutes
after this adjustment was
started and is automati-
cally set in the range of
2.35 to 2.45 V.
*
Selection is disable
when developer unit
is not installed.
(P.xxxxx)
141
M
Corrects the control
value of the auto-toner
sensor setup in 05-200.
*
Selection is disable
when developer unit
is not installed.
132
M
As the value increases,
the transformer output
increases correspond-
80
M
ingly. Remove the devel-
oper unit and install the
118
M
adjustment jig to make
adjustment.
129
M
(P.xxxxx)
97
M
56
M
56
M
38
M
50
M
Displaying of the relative
humidity latest value.
25
M
Displaying of the drum
temperature latest value.
25
M
Displaying of the temper-
ature latest value.
-
M
Perform this adjustment
before the replacement
of the developer mate-
rial. (The toner is forcibly
removed from the
cleaner.)
63
M
When the value
increases, the laser out-
put increases corre-
spondingly.
Proce-
2
dure
17
3
3
3
3
3
3
3
3
3
2
2
2
6
3