Procedure 17
[0][5]
[POWER]
[Digital keys]
* When the "storing" is not performed within 2 minutes after pressing the [START] button at the
manual adjustment, the "automatic adjustment" starts automatically.
Note:
Note:
The fuser roller temperature control at the adjustment mode is different from that at the normal
state.
Therefore, the problem of fusing efficiency may be occurred in the test copy at the adjustment
mode. In that case, turn ON the power normally, leave the equipment for approx. 3 minutes after
it has become ready state and then start up the adjustment mode again.
Test print pattern in Adjustment Mode (05)
Procedure
[0][5]
[POWER]
Test code
1
Grid pattern
2
Secondary scanning direction 33 gradation steps
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
Code
[START]
Code
[Digital keys]
Types of test pattern
value in RAM
Automatic
[INTERRUPT]
adjustment
Does not store
value in RAM
[FUNCTION
Adjustment
[ZOOMUP]
[ZOOMDOWN]
Test print
[INTERRUPT]
2 - 14
Stores
[POWER]
OFF/ON
CLEAR]
Set manually
[POWER]
OFF/ON
Remarks
TBD
TBD
December 2005 © TOSHIBA TEC