21)Uneven light distribution
Defective area
Original glass
Main charger
Discharge LED
Scanner
Exposure lamp
December 2005 © TOSHIBA TEC
Fig. 5-21
Step
Check items
1
Is the original glass dirty?
2
Are the needle electrode, main
charger grid and main charger case
dirty?
3
Is the discharge LED dirty?
4
Is any of the discharge LEDs off?
5
Are the reflector, exposure lamp, mir-
rors, lens, and original glass (espe-
cially the position of shading
correction plate) dirty?
6
Is the exposure lamp tilted?
7
Is the exposure lamp discolored or
degraded?
5 - 39
Prescription
Clean the original glass.
Clean or replace them.
Clean the discharge LED.
Replace the discharge LED.
Clean them.
Adjust the position of the exposure
lamp.
Replace the exposure lamp.