Stop Select In Open/Close Operation (Parameter P75); Open Arrival Signal Select (Parameter P76); Slip Arrival Judgment Frequency (Parameter P77); Slip Arrival Judgment Time (Parameter P78), Slip Open Arrival Substitute Select (Parameter P79) - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

STOP SELECT IN OPEN/CLOSE OPERATION (Parameter P75)

Caution
Depending on the STOP select in OPEN/CLOSE operation setting,
OPEN signal and CLOSE signal are both turned OFF sometimes,
but the automatic door does not stop. Use this function before security
and function operation of the lift system is completely confirmed.
(Secure personal safety before using this function.)
Failure to do so could lead to injury.
In OPEN/CLOSE operation, STOP operation can be selected when OPEN
signal and CLOSE signal are both turned OFF.
Data setting
0
Stops according to command signal (Factory setting data)
1
Does not stop (Carry out operation till arrival position.)
Note1) STOP operation in OPEN/CLOSE hold area is set with parameter d42.
Note2) STOP operation in fault ON operation of obstacle detection is set with
parameter P70.
OPEN ARRIVAL SIGNAL SELECT(Parameter P76)

SLIP ARRIVAL JUDGMENT FREQUENCY (Parameter P77)

SLIP ARRIVAL JUDGMENT TIME(Parameter P78)
SLIP OPEN ARRIVAL SUBSTITUTE SELECT(Parameter P79)
Caution
If there is no arrival signal, use this function before security and
function operation of the lift system is completely confirmed.
( Secure personal safety before using this function.)
Failure to do so could lead to injury.
There are two options for using door control encoder:
with arrival signal or without arrival signal.
If there is no arrival signal when testing door width, OPEN/CLOSE arrival
position is judged by slip detection and the door width is tested.
Judgment level and judgment time of slip arrival can be set with parameter
P77 and P78.