n16: Input signal
Lights: Closed between the input terminal and the common terminal.
Lights out: Opened between the input terminal and the common terminal.
Note) The input signal monitor lights when the input terminal is closed and
lights out when the input terminal is opened. It is independent of the
input signal logic setting.
n17: Output signal
Lights: When the relay coil is energized.
Lights out: When the relay coil is not energized.
LED
Input signal
position
n16
OPEN signal
CLOSE signal
OPEN arrival signal
CLOSE arrival signal
Safety sensor signal
OPEN speed change
signal
CLOSE speed change
signal
Encoder phase A signal
Encoder phase B signal
Output signal
n17
Relay 1 output signal
Relay 2 output signal
Relay 3 output signal
33