Explanation Of Control Circuit Terminals - Panasonic AAD03011 Instruction Manual

Elevator door controller
Table of Contents

Advertisement

Explanation of Control Circuit Terminals

Terminal
No.
Input terminal of Open Signal
(forward run operation)
Input terminal of Close Signal
(reverse run operation)
Input terminal of Open arrival signal
Input terminal of Close arrival signal
Input terminal of safety sensor
Input terminal of Open speed change signal
Input terminal of Close speed change signal
Common terminal of input signal 1 to 7
Built-in power supply (+) terminal (12 V DC)
Input terminal of encoder (phase A) signal
Input terminal of encoder (phase B) signal
Built-in power supply (-) terminal (12 V DC
common terminal)
Relay 1 contact output terminal (NO: at factory setting) P48
A 1
B 1
Relay 1 contact output terminal (NC: at factory setting) P48
C 1
Relay 1 contact output terminal (COM)
A 2
Relay 2 contact output terminal (NO: at factory setting) P49
B 2
Relay 2 contact output terminal (NC: at factory setting) P49
C 2
Relay 2 contact output terminal (COM)
A 3
Relay 3 contact output terminal (NO: at factory setting) P50
B 3
Relay 3 contact output terminal (NC: at factory setting) P50
C 3
Relay 3 contact output terminal (COM)
Transmission line + terminal
D
(RS485 serial communication signal)
Transmission line - terminal
D
(RS485 serial communication signal)
Terminal for setting terminator
(Transmission line- terminal and short-circuit)
E
Do not short the units other than the terminator.
V
Unused terminal
V
Unused terminal
20
Terminal Function
Related Parameter
No.
P08
P08
P43,P45,P47,P76,
d49
P43,P45,P47,P76,
d47
P43,P44
P09,P43,d48
P09,P43,d50
P09,P46,P52
P09,P46,P52
P48
P49
P50
P35 to P40
P35 to P40