NEC UNIVERGE SV8300 Command Manual page 522

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
AA
Y
No.
MEANING
15
Type of PRT/CCT/Q-SIG
16
Providing PRT/BRT blade with
ISDN Advice of Charge (AOC)
[UAE Only]
17
A-law/P-law setting of CD-PRTA
(PRT) blade
[Taiwan Only]
NOTE:
When providing A-law/
to 0/1 (A-law/
19
Selection of cable length (DTI)
20
Short/Long distance mode setting
of cable (CCT)
21
Receiving pulse level (CCT)
22
Local loopback setting (BRT/PRT)
(For test)
24
Local loopback setting (CCT)
(For test)
DTI/BRT/PRT/CCT FUNCTIONS
DATA
P
-law conversion for PRT in Taiwan, assign the second data of CMAA Y=17
P
-law) and set the SENSE switch of CD-PRTA blade to ON.
BLADE RESET
00
01
02
03
04
05
06
07
15
00
01
15
SETTING DATA
MEANING
0
E1 (2 Mbps)
1
T1 (1.5 Mbps)
0
To provide
1
Not provided
0
A-law
1
P-law
3
Depends on CM04 Y=10>00
0
0-40 m (0-131.2 ft.)
1
41-81 m (134.5-265.7 ft.)
2
82-122 m (269.0-400.2 ft.)
3
123-162 m (403.4-531.4 ft.)
4
163-200 m (534.6-656 ft.)
7
0-40 m (0-131.2 ft.)
0
Short distance
1
Long distance
0.91/1.70 V
1.74/0.84 V
0.59/0.84 V
0.42/0.45 V
0.32/0.45 V
0.21/0.20 V
0.16/0.10 V
0.10/not defined
0.91/1.70 V
0
ON
1
OFF
Local Loop Back
Payload Loop Back
Loop Back OFF
3-473
CMAA
: Default
RELATED
COMMAND
CM42>69, 70
NWA-033623-001 Rev.3.0
91ch3007.fm
NOVEMBER/12/2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents