Setting Bpdu Tunneling For The Pvst Configuration - HP A5830 Configuration Manual

Layer 2 lan switching
Hide thumbs Also See for A5830:
Table of Contents

Advertisement

Setting BPDU tunneling for the PVST configuration

Network requirements
As shown in
CE 1 and CE 2 are edge devices on the geographically dispersed network of User A. PE 1 and PE
2 are edge devices on the service provider network.
All ports that connect service provider devices and customer devices and those that interconnect
service provider devices are trunk ports and allow packets of any VLAN to pass through.
PVST is enabled for VLANs 1 through 4094 on User A's network.
After the configuration, CE 1 and CE 2 must implement consistent PVST calculation across the service
provider network, and the destination multicast MAC address carried in BPDUs must be 0x0100-0CCD-
CDD0.
Figure 30 Network diagram for configuring BPDU tunneling for PVST
CE 1
User A network 1
Configuration procedure
Configure PE 1.
1.
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE1> system-view
[PE1] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 1/0/1 as a trunk port and assign it to all VLANs.
[PE1] interface gigabitethernet 1/0/1
[PE1-GigabitEthernet1/0/1] port link-type trunk
[PE1-GigabitEthernet1/0/1] port trunk permit vlan all
# Disable STP on GigabitEthernet 1/0/1, and then enable BPDU tunneling for STP and PVST on it.
[PE1-GigabitEthernet1/0/1] undo stp enable
[PE1-GigabitEthernet1/0/1] bpdu-tunnel dot1q stp
[PE1-GigabitEthernet1/0/1] bpdu-tunnel dot1q pvst
Configure PE 2.
2.
# Configure the destination multicast MAC address for BPDUs as 0x0100-0CCD-CDD0.
<PE2> system-view
[PE2] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 1/0/2 as a trunk port and assign it to all VLANs.
[PE2] interface gigabitethernet 1/0/2
Figure
30:
PE 1
ISP network
BPDU tunnel
GE1/0/1
Trunk
PE 2
GE1/0/2
Trunk
CE 2
User A network 2
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents