Table B–9: MODBUS MEMORY MAP (Sheet 8 of 54)
ADDR
REGISTER NAME
2560
PMU 1 Ground Current Angle
2561
PMU 1 Positive Sequence Current Magnitude
2563
PMU 1 Positive Sequence Current Angle
2564
PMU 1 Negative Sequence Current Magnitude
2566
PMU 1 Negative Sequence Current Angle
2567
PMU 1 Zero Sequence Current Magnitude
2569
PMU 1 Zero Sequence Current Angle
256A
PMU 1 Frequency
256C
PMU 1 df/dt
256D
PMU 1 Configuration Change Counter
256E
Reserved (4 items)
2572
...Repeated for PMU 2
25A4
...Repeated for PMU 3
25D6
...Repeated for PMU 4
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Digital Input/Output states (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (16 items)
2F80
Remote Input States, one per register (64 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
Modbus file transfer (read/write)
3100
Name of file to read
Modbus file transfer values (read only)
3200
Character position of current block within file
3202
Size of currently-available data block
3203
Block of data from requested file (122 items)
Event recorder actual values (read only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
Event recorder commands (read/write)
3406
Event Recorder Clear Command
DCMA Input Values (Read Only) (24 modules)
34C0
DCMA Inputs 1 Value
34C2
DCMA Inputs 2 Value
34C4
DCMA Inputs 3 Value
34C6
DCMA Inputs 4 Value
34C8
DCMA Inputs 5 Value
34CA
DCMA Inputs 6 Value
34CC
DCMA Inputs 7 Value
34CE
DCMA Inputs 8 Value
34D0
DCMA Inputs 9 Value
34D2
DCMA Inputs 10 Value
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
-359.9 to 0
°
0 to 999999.999
A
-359.9 to 0
°
0 to 999999.999
A
-359.9 to 0
°
0 to 999999.999
A
-359.9 to 0
°
2 to 90
Hz
-327.67 to 327.67
Hz/s
0 to 655.35
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 65535
---
0 to 65535
---
0 to 400000000
---
0 to 65535
---
0 to 1
---
0 to 1
---
---
---
0 to 4294967295
---
0 to 65535
---
0 to 65535
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 1
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
-9999999 to 9999999
---
B.4 MEMORY MAPPING
STEP
FORMAT
DEFAULT
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F003
0
0.01
F002
0
0.01
F001
0
1
F001
0
1
F108
0 (Off)
1
F108
0 (Off)
1
F108
0 (Off)
1
F108
0 (Off)
1
F155
0 (Offline)
1
F108
0 (Off)
1
F001
0
1
F001
0
1
F050
0
1
F001
0
1
F126
0 (No)
1
F126
0 (No)
---
F204
(none)
1
F003
0
1
F001
0
1
F001
0
1
F003
0
1
F003
0
1
F050
0
1
F126
0 (No)
1
F004
0
1
F004
0
1
F004
0
1
F004
0
1
F004
0
1
F004
0
1
F004
0
1
F004
0
1
F004
0
1
F004
0
B
B-15