Toro 30506 Operator's Manual page 14

62in blower kit groundsmaster 200/3280-d/3320 series side discharge mowers
Hide thumbs Also See for 30506:
Table of Contents

Advertisement

1
2
Figure 25
1. Belt guard
2. Nut
2. Install the pulley guard onto the machine
3
Figure 26
1. Pulley guard
2. Nut
Note: Use existing hardware on the machine by
removing it and using it to install the guard.
3
g029097
3. Bolt
(Figure
26).
1
2
2
g029099
3. Bolt
13
Installing the New
Counterbalance Spring
(200 series traction units only)
Parts needed for this procedure:
1
Counterbalance spring
Procedure
To compensate for the additional weight of the blower
assembly, the original light counterbalance spring at the right
side of the machine, must be replaced with the heavier spring
included
(Figure
27).
1. Remove the hair pin cotter and clevis pin and slide the
spring assembly out of the retaining bracket.
2. Screw the spring off of the top and bottom mounting
brackets.
3. Screw the new heavy spring onto both mounting
brackets. Ensure that the spring is completely threaded
through all holes and it contacts the flat side of the
bracket.
1. Hair pin cotter
2. Clevis pin
3. Top bracket
4. Install the spring assembly into the retaining bracket
with a clevis pin and hairpin cotter.
14
Figure 27
4. Spring
5. Bottom bracket

Advertisement