Install Exhaust Guard
(European Compliance)
1. Position exhaust guard around muffler while aligning
mounting holes with holes in frame.
2. Secure exhaust guard to frame with (4) self tapping
screws.
Figure 6
1. Exhaust guard
Install ROPS
Important
Never weld or modify ROPS. Replace a
damaged ROPS, do not repair or revise. Any alteration of
ROPS must be approved by manufacturer.
1. Lower ROPS frame onto traction unit mounting
brackets, aligning mounting holes. Vent tube, secured to
ROPS, must be positioned on left side of machine.
2. Secure each side of roll bar to mounting brackets with
(2) flange head capscrews and locknuts (Fig. 7). Torque
fasteners to 60 ft–lbs.
3
2
5
4
Figure 7
1. ROPS
2. Mounting bracket
3. Vent tube
1
1
2
4. Fuel line vent tube hose
5. Hose clamp
15
3. Secure fuel line vent hose to vent tube on ROPS with
hose clamp.
Caution
Fuel line vent hose must be connected to vent tube
prior to starting engine or fuel will flow from hose.
Install Front Lift Arms
1. Remove (2) capscrews securing lift arm pivot shaft link
to lift arm pivot shafts. Remove and retain pivot shaft
link and capscrews (Fig. 8).
2
Figure 8
1. Lift arm pivot shaft link
2. Insert a pivot rod into each (R.H. & L.H.) lift arm and
align mounting holes (Fig. 9).
Figure 9
1. Lift arm
3. Secure pivot rods to lift arms with a 5/16 – 18 x 7/8" lg.
capscrew.
4. Insert R.H. & L.H. lift arms onto lift arm pivot shafts.
Secure with lift arm pivot shaft link and capscrews
previously removed. Torque capscrews to 70 ft–lbs.
1
2. Lift arm pivot shaft
1
2
2. Pivot rod