Maintenance; Lubrication; Bearing Alignment - Toro 30393 Operator's Manual

Debris blower traction unit
Hide thumbs Also See for 30393:
Table of Contents

Advertisement

Maintenance

Lubrication

The debris blower has bearings and bushings that must be
lubricated regularly. If the machine is operated under normal
conditions, lubricate the bearings with #2 general-purpose,
lithium-based grease after every 8 hours of operation or daily,
whichever comes first. Lubricate the fittings immediately
after every washing, regardless of the interval listed.
The lubrication points and quantities are as follows:
Fan shaft—2 (Figure 10)
Figure 10
Castor arm tube (Figure 11)
Castor wheel (Figure 11)
G003730
Figure 11
Greasing the Attachment Adapter
If the locking lever on the attachment adapter does not pivot
freely and easily, apply a light coat of grease to the area shown
in Figure 12.

Bearing Alignment

If the motor mounting brackets are ever removed, they must
be realigned before the debris blower is operated. Refer to the
Part Catalog for the Alignment Tool part number.
1. Make sure that the mounting brackets are installed to
the blower housing but the bolts and nuts are loose
(Figure 13).
1
2
1. Alignment tool
2. Mounting bracket
2. Insert the bearing alignment tool through the mounting
brackets and into the fan coupler (Figure 13). Make
sure that the spider coupler (Figure 14) is not in the
coupler.
13
G003731
Figure 12
2
3
G003814
Figure 13
3. Fan coupler