Indoor Unit

5. SELECTING THE INSTALLATION SITE

5-1. Indoor Unit
AVOID:
areas where leakage of flammable gas may be
expected.
places where large amounts of oil mist exist.
direct sunlight.
locations near inverter lamps which may affect the
performance of the unit.
locations near heat sources which may affect the
performance of the unit.
locations where external air may enter the room
directly. This may cause "sweating" on the air dis-
charge ports, causing them to spray or drip.
locations where the remote controller will be splashed
with water or affected by dampness or humidity.
installing the remote controller behind curtains or
furniture.
locations where the receiver in the indoor unit is
exposed to the inverter lamp light. Faulty operation
of the unit occurs.
locations where high-frequency emissions are
generated.
DO:
select an appropriate position from which every
corner of the room can be uniformly cooled.
select a location where the ceiling is strong enough
to support the weight of the unit.
select a location where tubing and drain pipe have
the shortest run to the outdoor unit.
allow room for operation and maintenance as well as
unrestricted air flow around the unit.
install the unit within the maximum elevation
difference above or below the outdoor unit and within
a total tubing length (L) from the outdoor unit as
detailed in the installation instructions packed with
the outdoor unit.
allow room for mounting the remote controller about
3 ft. off the floor, in an area that is not in direct
sunlight nor in the flow of cool air from the indoor
unit.
If the indoor unit is installed on the ceiling where the
temperature or humidity inside is high (over 86°F(30°C)
/RH: 70%), add insulating material to the surface of the
unit to avoid dew condensation.
NOTE
Air delivery will be degraded if the distance from the
floor to the ceiling is greater than 10 ft.
Ceiling (Type T1)
Ceiling
Min. 10 inch
Min. 10 inch
Front view
NOTE
The rear of the indoor unit can be
installed flush against the wall.
Low Silhouette Ducted (Type F1)
4-Way Cassette (Type U1)
10 in.
10 in.
Shows Low Silhouette Ducted Type only
9-27/32"
(250 mm)
Wall Mounted (Type K1)
Min.
6 inch
Wall Mounted (Type K2)
The air inlet and outlet of the indoor unit must be free of any
obstructions to allow air to spread throughout the room.
1. The
indoor unit must be within a maintenance soace.
min.
2" (5 cm)
1-119
1. Specifications
Air
Ceiling
discharge
Wall
Air intake
Min. 2 ft.
Side view
3 ft.
3 ft.
10 in.
3 ft.
3 ft.
Min.8 ft.
25-19/32"
(650 mm)
Type F2
Min.
6 inch
Min.
12 inch
min. 3" (7.5 cm) min.
2" (5 cm)
Front View
1