Page 1
Indoor Unit Nominal Capacity Type Indoor Unit Type Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating instructions supplied with the outdoor unit. Outdoor Unit...
INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. • Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
Page 4
• For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. • Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
OPERATION CONDITION Use this air conditioner under the following temperature range. Single Split System Indoor Outdoor Temperature range (°F/°C) *DBT *WBT *DBT *WBT Max. 90/32 77/25 115/46 –/– Cooling Min. 64/17.8 57/14 14/-10 –/– Max. 86/30 –/– 75/24 64/17.8 Heating Min.
NAMES OF PARTS INDOOR UNIT LOW SILHOUETTE DUCTED F2 type (standard static pressure) Bolt anchor* Air outlet duct* Suspension bolt* Air intake duct* Air outlet grille* Indoor unit Air intake grille* Ceiling material* * Field supplied Timer Remote Controller (Optional parts) NOTE Refer to the Operating Instructions attached to the optional Timer Remote...
SPECIAL REMARKS ‘‘DRY’’ Operation How it works • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. • In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating.
CARE AND CLEANING 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard. Air Intake and outlet side Clean the air intake and outlet side of the indoor unit with a vacuum cleaner brush, or wipe (Indoor Unit)
TROUBLESHOOTING If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. INDOOR UNIT Symptom Cause Noise Sound like streaming water during •...
CHECK BEFORE REQUIRING SERVICES Symptom Cause Remedy Air conditioner does not run at Power failure or after power failure Press ON/OFF operation button on remote controller all although power is turned again. Operation button is turned off. • Switch on power if breaker is turned off. •...