Rs-485 Connections - Bosch VEZ-400 Series Installation Manual

Autodome 4000 mini ptz dome
Hide thumbs Also See for VEZ-400 Series:
Table of Contents

Advertisement

AUTODOME 4000 Mini PTZ Dome
6.2

RS-485 Connections

The camera can be controlled by an external device or control system using an RS-485
duplexer. The total length of the cable for communication should not exceed 1 km (3937 ft). If
the distance between the camera and the control room is greater than 1 km (3937 ft), Bosch
recommends using a repeater (not supplied).
Notice!
The wire shield must be tied to signal at both ends, if 2-wire twisted pair is used.
Notice!
When the RS-485 signal is looped through, ensure that (only) the last device is terminated
properly. Improper RS-485 wiring or termination may result in unreliable system operation.
Use a 2-wire (shielded), half-duplex, differential, multi-drop with the following attributes:
Wire Type
Distance
Gauge
Impedance
Table 6.1: RS-485 Wire Specifications
The following table shows the terminal connections for the 2-pin terminal block RS-485
connections (see , page 26, item 5):
Number
1
2
Table 6.2: 2-pin Terminal Block Connections
Notice!
When the camera's RS-485 port is connected to a MIC-BP3 Biphase convertor, the camera's
TRX+ should be connected to the convertor's RxB, and TRX- should be connected to RxA. The
camera's baud rate should be set to 9600, and the protocol should be set to Bosch OSRD.
Also make sure that the camera ID is configured correctly. For further details on setting up
the MIC-BP3, please refer to the separate MIC-BP3 Bi-Phase Converter Card Installation and
Operation Manual.
Bosch Security Systems, Inc.
2-wire Shielded Twisted Pair
1.2 Km (3937 ft)
0.511 mm (24 AWG)
120 Ω
Signal
Color
TRX +
Sky
TRX -
White
Installation Manual
Connection | en
27