Mitsubishi Electric FR-A800 Installation Manuallines page 52

Hide thumbs Also See for FR-A800:
Table of Contents

Advertisement

DRIVE THE MOTOR
Parameter Name
C9
Current output bias
(930)
current
*9,*11
C10
Current output gain
(931)
signal
*9,*11
C11
Current output gain
(931)
current
*9,*11
Terminal 4 bias
C38
command (torque/
*9
(932)
magnetic flux)
Terminal 4 bias
C39
(torque/magnetic
*9
(932)
flux)
Terminal 4 gain
C40
command (torque/
*9
(933)
magnetic flux)
Terminal 4 gain
C41
(torque/magnetic
*9
(933)
flux)
C42
PID display bias
*9
coefficient
(934)
C43
PID display bias
*9
analog value
(934)
C44
PID display gain
*9
coefficient
(935)
C45
PID display gain
*9
analog value
(935)
Input voltage mode
977
selection
Parameter copy
989
alarm release
990
PU buzzer control
PU contrast
991
adjustment
Operation panel
992
setting dial push
monitor selection
Droop break point
994
gain
Droop break point
995
torque
*2
For FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower
*3
For FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher
*9
The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).
*11
The setting is available only with the CA type.
46
Initial
Setting Range
Value
0%
0 to 100%
0 to 100%
100%
0 to 100%
100%
0 to 400%
0%
20%
0 to 300%
150%
0 to 400%
100%
0 to 300%
0 to 500.00,
9999
9999
20%
0 to 300.0%
0 to 500.00,
9999
9999
100%
0 to 300.0%
0
0, 1
*2
*2
10
10
3
3
100 *
100 *
1
0, 1
58
0 to 63
0 to 3, 5 to 14,
17 to 20, 22 to
35, 38, 40 to 45,
0
50 to 57, 61, 62,
64, 67, 87 to 97,
100
0.1 to 100%,
9999
9999
100%
0.1 to 100%
Parameter Name
997
Fault initiation
PM parameter
998
initialization
Simple
Simple
Simple
Automatic parameter
999
Simple
Simple
Simple
setting
Lq tuning target
1002
current adjustment
coefficient
Notch filter
1003
frequency
1004
Notch filter depth
1005
Notch filter width
1006
Clock (year)
1007
Clock (month, day)
1008
Clock (hour, minute)
Trace operation
1020
selection
1021
Trace mode selection
1022
Sampling cycle
Number of analog
1023
channels
1024
Sampling auto start
Trigger mode
1025
selection
Number of sampling
1026
before trigger
Initial
Setting Range
Value
9999
0 to 255, 9999
0, 3003, 3103,
0
8009, 8109,
9009, 9109
1, 2, 10 to 13,
9999
20, 21, 9999
50 to 150%,
9999
9999
0
0, 8 to 1250Hz
0
0 to 3
0
0 to 3
2000
2000 to 2099
101 to 131, 201
to 229, 301 to
331, 401 to 430,
501 to 531, 601
to 630, 701 to
101
731, 801 to 831,
901 to 930,
1001 to 1031,
1101 to 1130,
1201 to 1231
0 to 59, 100 to
159, 200 to 259,
300 to 359, 400
to 459, 500 to
559, 600 to 659,
700 to 759, 800
to 859, 900 to
959, 1000 to
1059, 1100 to
1159, 1200 to
1259, 1300 to
0
1359, 1400 to
1459, 1500 to
1559, 1600 to
1659, 1700 to
1759, 1800 to
1859, 1900 to
1959, 2000 to
2059, 2100 to
2159, 2200 to
2259, 2300 to
2359
0
0 to 4
0
0 to 2
2
0 to 9
1 to 8
4
0
0, 1
0
0 to 4
90%
0 to 100%

Hide quick links:

Advertisement

Table of Contents
loading