Mitsubishi Electric FR-A800 Installation Manuallines page 42

Hide thumbs Also See for FR-A800:
Table of Contents

Advertisement

DRIVE THE MOTOR
Parameter Name
Backlash
141
acceleration
stopping time
Backlash
142
deceleration
stopping frequency
Backlash
143
deceleration
stopping time
Speed setting
144
switchover
PU display language
145
selection
Acceleration/
147
deceleration time
switching frequency
Stall prevention level
148
at 0V input
Stall prevention level
149
at 10V input
Output current
150
detection level
Output current
151
detection signal
delay time
Zero current
152
detection level
Zero current
153
detection time
Voltage reduction
154
selection during stall
prevention operation
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
OL signal output
157
timer
AM terminal function
158
selection
Automatic switch-
over frequency range
159
from bypass to
inverter operation
User group read
160
Simple
Simple
Simple
selection
Frequency setting/
161
key lock operation
selection
Automatic restart
after instantaneous
162
power failure
selection
First cushion time for
163
restart
First cushion voltage
164
for restart
*12
The setting value "60" is only available for Pr. 178, and "61" is only for Pr. 179.
*13
The setting values "92, 93, 192, 193" are only available for Pr. 190 to Pr. 194.
*15
Differs according to model types (standard model, separated converter type, IP55 compatible model).
36
Initial
Setting Range
Value
0.5s
0 to 360s
1Hz
0 to 590Hz
0.5s
0 to 360s
0, 2, 4, 6, 8, 10,
4
102, 104, 106,
108, 110, 112
1
0 to 7
0 to 590Hz,
9999
9999
0 to 400%
150%
200%
0 to 400%
150%
0 to 400%
0s
0 to 10s
5%
0 to 400%
0.5s
0 to 10s
1
0, 1, 10, 11
0, 10
0
0 to 31, 100,
0
101
0 to 25s, 9999
0s
1 to 3, 5 to 14,
17, 18, 21, 24,
32 to 34, 50, 52
1
to 54, 61, 62,
67, 70, 87 to 90,
91 to 98
9999
0 to 10Hz, 9999
0
0, 1, 9999
0
0, 1, 10, 11
0 to 3, 10 to 13
0
0s
0 to 20s
0%
0 to 100%
Parameter Name
Stall prevention
165
operation level for
restart
Output current
166
detection signal
retention time
Output current
167
detection operation
selection
168
Parameter for manufacturer setting.
Do not make setting.
169
Watt-hour meter
170
clear
Operation hour
171
meter clear
User group
172
registered display/
batch clear
User group
173
registration
174
User group clear
STF terminal
178
function selection
STR terminal
179
function selection
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
RT terminal function
183
selection
AU terminal function
184
selection
JOG terminal
185
function selection
CS terminal function
186
selection
MRS terminal
187
function selection
STOP terminal
188
function selection
RES terminal
189
function selection
RUN terminal
190
function selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal
195
function selection
ABC2 terminal
196
function selection
Initial
Setting Range
Value
150%
0 to 400%
0.1s
0 to 10s, 9999
0
0, 1, 10, 11
9999
0, 10, 9999
0, 9999
9999
0
9999, (0 to 16)
9999
0 to 1999, 9999
0 to 1999, 9999
9999
60
61
0
1
2
0 to 20, 22 to
28, 37, 42 to 47,
3
50, 51, 60 to 62,
64 to 74, 76 to
4
80, 87, 92, 93,
*12
9999
5
6
24/10/24
15
*
25
62
0
0 to 8, 10 to 20,
22, 25 to 28, 30
to 36, 38 to 54,
1
56, 57, 60, 61,
63, 64, 68, 70,
2/9999/2
79, 84, 85, 90 to
15
99, 100 to 108,
*
110 to 116, 120,
122, 125 to 128,
3
130 to 136, 138
to 154, 156,
4
157, 160, 161,
163, 164, 168,
170, 179, 184,
99
185, 190 to 199,
200 to 208, 300
*13
to 308, 9999
9999

Hide quick links:

Advertisement

Table of Contents
loading