Mitsubishi Electric FR-A800 Installation Manuallines page 48

Hide thumbs Also See for FR-A800:
Table of Contents

Advertisement

DRIVE THE MOTOR
Parameter Name
Second brake
647
operation time at
stop
Second deceleration
648
detection function
selection
Second brake
650
opening current
selection
Second brake
651
operation frequency
selection
Speed smoothing
653
control
Speed smoothing
654
cutoff frequency
Analog remote
655
output selection
Analog remote
656
output 1
Analog remote
657
output 2
Analog remote
658
output 3
Analog remote
659
output 4
Increased magnetic
excitation
660
deceleration
operation selection
Magnetic excitation
661
increase rate
Increased magnetic
662
excitation current
level
Regeneration
665
avoidance frequency
gain
Power failure stop
*17
668
frequency gain
Tuning data unit
684
switchover
686
Maintenance timer 2
Maintenance timer 2
687
warning output set
time
688
Maintenance timer 3
Maintenance timer 3
689
warning output set
time
Deceleration check
690
time
Second free thermal
692
reduction frequency
1
Second free thermal
693
reduction ratio 1
*17
Setting available for standard models and IP55 compatible models.
42
Initial
Setting Range
Value
0.3s
0 to 5s
0
0, 1
0
0, 1
0
0, 1
0%
0 to 200%
20Hz
0 to 120Hz
0
0, 1, 10, 11
1000%
800 to 1200%
800 to 1200%
1000%
1000%
800 to 1200%
1000%
800 to 1200%
0
0, 1
9999
0 to 40%, 9999
100%
0 to 300%
100%
0 to 200%
100%
0 to 200%
0
0, 1
0
0 (1 to 9998)
9999
0 to 9998, 9999
0
0 (1 to 9998)
9999
0 to 9998, 9999
0 to 3600s,
1s
9999
0 to 590Hz,
9999
9999
100%
1 to 100%
Parameter Name
Second free thermal
694
reduction frequency 2
Second free thermal
695
reduction ratio 2
Second free thermal
696
reduction frequency 3
699
Input terminal filter
Maximum motor
702
frequency
Induced voltage
706
constant (phi f)
Motor inertia
707
(integer)
711
Motor Ld decay ratio
712
Motor Lq decay ratio
Starting resistance
717
tuning compensation
Starting magnetic
721
pole position
detection pulse width
Motor inertia
724
(exponent)
Motor protection
725
current level
Second motor
738
induced voltage
constant (phi f)
Second motor Ld
739
decay ratio
Second motor Lq
740
decay ratio
Second starting
741
resistance tuning
compensation
Second motor
742
magnetic pole
detection pulse width
Second motor
743
maximum frequency
Second motor inertia
744
(integer)
Second motor inertia
745
(exponent)
Second motor
746
protection current
level
Second motor low-
speed range torque
747
characteristic
selection
Initial
Setting Range
Value
0 to 590Hz,
9999
9999
100%
1 to 100%
0 to 590Hz,
9999
9999
9999
5 to 50ms, 9999
0 to 400Hz,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
9999
10 to 999, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to
6000µs,10000
9999
to 16000µs,
9999
9999
0 to 7, 9999
100 to 500%,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000µs,
9999
10000 to
16000µs,9999
0 to 400Hz,
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
100 to 500%,
9999
9999
0, 9999
9999

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents