iPF6400S Basic Guide
7
Move the White Calibration Tile Holder in the
direction of the arrow and remove it from the
Up-down Unit.
Important
8
Push the (a) part of the White Calibration Tile
Holder and remove the White Calibration Tile.
Important
9
Wipe the surface of the White Calibration Tile clean with a dry, soft cloth.
If the white part is particularly dirty, use a damp cloth that you have wrung out completely to wipe
the surface of the White Calibration Tile clean and use a dry cloth to dry the surface.
10
Place the White Calibration Tile in the White
Calibration Tile Holder and mount it in the
position shown in the diagram while pushing
down on the (a) part.
When installing the White Calibration Tile, make
sure it is facing the appropriate direction.
58
• Do not touch the (a) part of the White
Calibration Tile Holder except when
removing the White Calibration Tile.
Doing so may cause the White Calibration
Tile to fall, which can lead to damage.
• Never touch the white part of the White
Calibration Tile.
If the white part is dirty, the printer may
not be able to obtain the correct color
measurement results.