Sharp UP-600 Service Manual page 22

Hide thumbs Also See for UP-600:
Table of Contents

Advertisement

ER-A5RS CON3
S1-1
S1-2
S1-3
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
ER-A5RS CON4
S1-4
S1-5
S1-6
0
0
0
Disabled
0
0
1
No setting is allowed (Standard RS)
0
1
0
CHANNEL 2
0
1
1
CHANNEL 3
1
0
0
CHANNEL 4
1
0
1
CHANNEL 5
1
1
0
CHANNEL 6
1
1
1
CHANNEL 7
How to exit the program
Press the CANCEL key to exit the program.
4)-2. CH1 Check
Checking
If any channel is not set, the error message (ERROR: CH1) ap-
pears. When any channel is set, the following checks are per-
formed.
i. Control signal check
ERn
RSn
DRn
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
The program performs the read checks of the above inputs and
interrupt checks of CS, CI, and CD.
During the read check, ER and RS are changed over in the above
order, checking the logic of DR, CI, CD and CS.
If the check result does not agree with the logic in the table, the
error message appears. The ON in the table means active low
and the OFF means active high.
In the interrupt check, the CS, CI and CD interrupts are permitted
one by one (The mask is canceled.).
The error message appears if an interrupt does not occur when
each signal is active or if an interrupt occurs when each signal is
not active.
Four cycles of the above check is performed.
ii. Data transfer check
As check data, loop back data transfer of 256 bytes of 00H - 0FFH
is performed. The baud rate is 38400 bp.
CHANNEL
Disabled
No setting allowed (Standard RS)
CHANNEL 2
CHANNEL 3
CHANNEL 4
CHANNEL 5
CHANNEL 6
CHANNEL 7
CHANNEL
Cin
CDn
CSn
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
ON
ON
iii. TIMER CHECK (RS232 ON BOARD TIMER)
Before starting the check ii, perform the RCVDT start of the timer
you want to check and set to 5 ms. Make sure::
No TRQ- is generated during the implementation of check ii.
TRQ- is generated at 5 ms after check ii is completed.
Display
RS232 CH1 Check
PASS!!(or ERROR!!)
All the details of errors are printed on the journal.
ERROR
ERROR print
No.
1
ER-DR : ERROR
2
ER-CI : ERROR
3
RS-CD : ERROR
4
RS-CS : ERROR
5
CI INT : ERROR
6
CD INT : ERROR
7
CS INT : ERROR
8
TXEMP : ERROR
9
TXEMP INT : ERROR
10
TXRDY : ERROR
11
TXRDY INT : ERROR
12
RCVRDY : ERROR
13
RCVRDY INT : ERROR RCVRDY interrupt does not
14
SD-RD : ERROR
15
SD-RD : ERROR
16
TIMER : ERROR
17
TIMER INT : ERROR
How to exit the program
Press the CANCEL key to exit the program.
Details of ERROR
ER-DR LOOP ERROR
ER-CI LOOP ERROR
RS-CD LOOP ERROR
RS-CS LOOP ERROR
No CI interrupt occurs.
No CD interrupt occurs.
No CD interrupt occurs.
TXEMP is not set.
TXEMP interrupt does not
occur.
TXRDY is not set.
TXRDY interrupt does not
occur.
RCVRDY is not set.
(Not possible to receive.
TRQ- occurs during the
implementation of check ii.)
occur.
SD-RD LOOP ERROR
(DATA ERROR)
SD-RD LOOP ERROR
(DATA ERROR)
TIMER ERROR
(After check ii is completed)
TRQ1- interrupt does not
occur.