3) -2. 02FD
No
Procedure on P.C. side
1
Install "02FD.EXE" on the P.C.
ALL RAM Data UpLoad : Go to "2"
ALL RAM Data DownLoad : Go to "9"
2
ALL RAM Data UpLoad
Connect P.C. and UP-600 (CH2) via RS232. (Fig 1)
4
Execute "02FD.EXE" on P.C.
*Don't execute the other Software at the same time.
5
Set the Communication method by "Setting" Button.
Push "OK" Button.
6
Push "Receive Start" Button.
And Select the Receiving File.
7
Communication starts.
8
UpLoad is completed.
The initial Window is shown.
Push "Exit" Button.
9
ALL RAM Data UpLoad
Connect P.C. and UP-600 (CH2) via RS232. (Fig 1)
No
Procedure on UP-600 side
2
Enter the SRV mode.
Select " 2 SETTING ".
Select " 14 BACKUP SEND"
3
UP-600 shows
BACKUP SEND
SEND DATA
SPEED
7
Push TL key. UP-600 shows
SENDING
8
UpLoad is completed.
The SETTING menu is shown.
9
Enter the SRV mode.
Select " 2 SETTING".
Select " 15 BACKUP RECEIVE"
10
UP-600 shows
BACKUP RECEIVE
SPEED
Push CA/AT key.
ALL RAM
PROGRAMMED SPEED
00000
PROGRAMMED SPEED