Switch Integration Device Administration
starts, you see the SMDI VIEW MODE screen as shown in the following diagram.
below:
SMDI Idle
When the SID receives calls, the screen changes to show the SMDI packet being
sent to the INTUITY System.
The screen appears similar to the following example:
SMDI MWI:
CPID:
For more information on view modes, refer to Ap pendix B, "Using Views During
Integration", in this document. Continue to the procedure in the next section,

"Administer Serial Data Links."

Administer Serial Data Links
The SID assigns default configurations to both the MCI and SMDI communication
ports. You need to check the SID to make sure the defaults are set correctly and
match the requirements of your integration. The SID sets the defaults shown in
Table 8-1 for the serial data links.
Table 8-1. Serial Data Link Default Values
Link Type
SMDI:
MCI:
8-8
Issue 2 December 1995
0OP:MWI 0000202!.
..MD0010001D 0000201 ...
Settings
1200 baud
7 data bits
1 stop bit
EVEN parity
1200 baud
7 data bits
1 stop bit
EVEN parity