Siemens SITRANS LCS100 Operating Instructions Manual page 41

Capacitance switches
Table of Contents

Advertisement

Item
Out 2:
Switchpoint:
uncovered
to covered *
Actual
switchpoint
setting is
done by:
* If register is written, register 127 is set to "1 = IO-Link".
** Factory setted values for switchpoints can slightly deviate from the stated values, since factory
Item
DIagnostics:
Operating
hours
Temperature
electronic*
actual
Temperature
electronic*
min.
Temperature
electronic*
max.
Functional
check
* Ambient temperature of the electronic inside the enclosure (outside process)
Identification:
Ordercode
ISDU = Indexed Service Data Unit
R/W = read/write
FSL = Fail safe Low = output contact open with uncovered sensor
FSH = Fail safe High = output contact open with covered sensor
SITRANS LCS100 I/O Link Version
Operating Instructions, 05/2023, A5E52382716-AA
ISDU
Access Length
(dec)
113
R/W
127
R
calibration is done by use of the potentiometer. This does not influence the proper function of the
unit.
ISDU
Access Length
(dec)
128
R
131
R
132
R
133
R
134
R/W
160
R
Data
Value Range
(byte)
type
2
UInt
0 ... 10000 (equates to 0.00% -
100.00%)
1
UInt
0 = Potentiometer
1 = IO-Link
Data
Value Range
(byte)
type
4
UInt
0 ... 2^32
1
Int
-128 ... +127 °C
1
Int
-128 ... +127 °C
1
Int
-128 ... +127 °C
1
UInt
0 = No functional-check
1 = Simulate uncovered probe
2 = Simulate covered probe
64
Strin
g
Operating
6.3 Operation with IO-Link
Default
value
4.00% **
0
Default
value
0
127°C
-128°C
0
41