Command 966 - Enable/Disable The Automatic Stepping Of Locations; Command 999 - Display The Control Panel Firmware Version Number - Bosch Solution 2000 Installation Manual

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

28
en | Configuration
Location
033
034 and 039
392
403
424
427
428 to 431,
434
435
Table 5.2: Command 965 Defaults
5.1.8

Command 966 - Enable/Disable the Automatic Stepping of Locations

This command allows the automatic stepping of locations when programming in Installer's
Programming Mode.
Programming with the codepad provides no visual indication that Auto Step Mode is enabled.
To enable the automatic stepping of locations:
1.
2.
To disable the automatic stepping of locations:
Enter [9 6 6 #]. Two beeps sound.
Example (Auto Step Enabled)
To enter the Primary Telephone Number 02 (pause) 9672 1055 when auto step is enabled:
1.
2.
Example (Auto Step Disabled)
To enter the Primary Telephone Number 02 (pause) 9672 1055 when auto step is disabled:
Press [0 #].
You are positioned at Location 000 (the Primary Telephone Number for Receiver 1).
To program the number, press:
[10 * # 2 * # 13 * # 9 * # 6 * # 7 * # 2 * # 1 * # 0 *# 5 * # 5 * # 0 *]
When working with a text codepad, go to Menu 82 [Adapter auto step] to switch automatic
stepping enable/disable.
5.1.9

Command 999 - Display the Control Panel Firmware Version Number

When using the codepad, this command displays the firmware version of the control panel.
To display the control panel firmware version number:
1.
2017.10 | 03 | F.01U.298.026
Description
Transmission Format
Subscriber ID Number
Zone Status Reporting Options
Arm/Disarm Reporting Options
System Status – Access Denied
System Status Reporting Options
Test Report Time
Test Reporting Options
Enter the Installer Code (default = 1234) and press [#] to enter Installer's Programming
Mode. Two beeps sound and the STAY and AWAY indicators flash on the codepad to
indicate you entered Installer's Programming Mode. The codepad displays the data stored
in Location 000.
Enter [9 6 6 #]. Two beeps sound.
Press [0 #]. You are positioned at Location 000 (the Primary Telephone Number for
Receiver 1).
Program the number by pressing: [10 * 2 * 13 * 9 * 6 * 7 * 2 * 1 * 0 * 5 * 5 * 0*]
Enter the Installer Code (the default is 1234) and press [#] to enter Installer's
Programming Mode. If you are using the codepad, the STAY and AWAY indicators flash to
indicate you entered Installer's Programming Mode.
Installation Guide
Default Value
Setting
4
Domestic
0, 0, 0, 0, 0, 1
1 Beep
2
Receiver 2 only
2
Receiver 2 only
6
Access Denied
2
Receiver 2 only
0, 0, 0, 0, 0
Test Reports
1
Receiver 1 only
Bosch Security Systems, Inc.
Control Panel

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents