en | Communication Information
Notice!
Set the Ring Count for the answering machine or facsimile machine to a value greater than
two rings. Four to six rings is preferred.
Program a 0 into this location to disable the control panel from answering an incoming call.
11.16

Telephone Line Fail Options

Item
Telephone Line Fail
Options
This location has three options. You can select any combination of these options by
programming a single value. Calculate this value by adding the option bit numbers together.
The control panel monitors the telephone line. If the telephone line is cut or disconnected for
longer than 40 sec, the control panel lights the FAULT indicator on the codepad. The FAULT
indicator is extinguished after the telephone line is restored for longer than 40 sec.
Notice!
Options 2 and 4 do not operate unless you also enable Option 1.
1 – Display FAULT indicator when the Telephone Line Fails
When this options is selected, the FAULT indicator flashes and the codepad buzzer beeps
once per min if the control panel detects that the telephone line is disconnected.
2 – Sound Alarm when System Is Armed
You must also select Option 1 to use this option. If the control panel detects that the
telephone line is disconnected when the system is armed, the horn speaker, bell, and strobe
outputs are activated. If only one audible alarm per arming cycle is required, select the
Lockout Telephone Line Fail Alarm option (2) in Location 179 (refer to Communication Options
3, page 78).
4 – Sound Alarm when System Is Disarmed
You must also select Option 1 to use this option. If the control panel detects that the
telephone line is disconnected when the system is disarmed, the horn speaker, bell, and
strobe outputs are activated. If only one audible alarm per arming cycle is required, select the
Lockout Telephone Line Fail Alarm option (2) in Location 179.
Notice!
If you program 7 in this location, the horn speaker, bell, strobe, and outputs are all activated
when the system is armed or disarmed.
2017.10 | 03 | F.01U.298.026
Location
Option
0176
1 = Display FAULT Indicator when
telephone line fails
2 = Sound alarm when system is armed
4 = Sound alarm when system is
disarmed
8 = Reserved