When you wire the module to a control panel, use the module's terminal strip labeled with
PWR, A, B, and COM.
LED descriptions
The module includes one blue heartbeat LED to indicate that the module has power and to
indicate the module's current state.
Flash pattern
Flashes once every 1 second
3 quick flashes every 1 second
ON steady
OFF steady
4.9

B426/B426-M Conettix Ethernet Communication Modules

The B426 Conettix Ethernet Communication Module is a four-wire powered SDI, SDI2, or
Option bus device that provides two-way communication with compatible control panels over
IPv4 or IPv6 Ethernet networks.
Typical applications include:
The B426 is built for a wide variety of secure commercial and industrial applications. Flexible
end-to-end path supervision, AES encryption, and anti-substitution features make B426
desirable for high security and fire monitoring applications. It is capable as a stand-alone path
or it can be used in conjunction with another communication technology. For Fire Monitoring
applications, the B426 meets UL864 and NFPA72 standards for Single Communication
Technology with approved Bosch control panels.
4.10

B450/B450-M Conettix Plug-in Communicator Interfaces

Notice!
For B450-M only: Scan the QR code with your smart phone to access the control panel app
RSC+.
The Conettix Plug-in Communicator Interface is a four-wire powered SDI2, SDI, or option bus
device that provides two-way communication with compatible control panels over commercial
cellular networks using a plug-in communicator (available separately).
Use the B450 in combination with a plug-in communicator for primary or backup alarm
communication, remote control panel programming and other remote applications. The B450
supports Conettix IP protocol with full authentication, 256 bit AES encryption and resistance
to Denial of Service attacks. Use the B450 to add cellular network communications to existing
or new commercial security and fire installations.
Switch addressing
Use the address switch to assign a bus address or setup for USB or SMS configuration where
required. The address switch allows bus address selection.
Bosch Security Systems, Inc.
Reporting and path supervision to a Conettix Communications Receiver/Gateway.
Remote administration and control with A-Link Plus or our Remote Security Control
application for handheld devices.
Connection to building automation and integration applications.
Function
Indicates normal operation state.
Indicates the module is in a "no communication" state
resulting in an SDI2 communication error.
A trouble condition is exist..
Module is not powered or some other trouble condition is
prohibiting the module from controlling the heartbeat LED.
Installation Guide
Accessories | en
21
2017.10 | 03 | F.01U.298.026

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents