58
en | System Functions
7.4.10
Reset Latching Outputs
Holding down [7] until two beeps sound resets any output that is programmed to remain on
after it is activated. The output must be programmed with a latching polarity.
See also
–
7.4.11
Change the Codepad Buzzer Tone
Holding down [8] continuously changes the tone of the buzzer in the remote codepad. There
are 50 different tones from 1500 Hz to 5000 Hz. In an installation with multiple codepads, you
can set a different tone for each codepad.
To change the buzzer tone:
1.
2.
Notice!
Every time the system is powered down, you must reset each codepad to its individual tone
using this function.
On partitioned control panels, this hold-down function also indicates the area to which the
codepad belongs.
To determine the area to which the codepad belongs:
1.
2.
7.4.12
Send Test Report
Holding down [9] until two beeps sound transmits a Test Report (Contact ID Event Code 602)
to test the reporting capabilities of the system without activating the sirens.
2017.10 | 03 | F.01U.298.026
Output Polarity, page 130
Press and hold [8] continuously. The tone of the buzzer increases in pitch.
Release [8] button when you hear the desired tone.
Press and hold [8] until two beeps sound. A zone indicator lights to show the area to
which the codepad belongs.
–
Zone 1 = Area 1 codepad
–
Zone 2 = Area 2 codepad
–
Zone1,2 = Common Codepad for both Area1 and Area2
–
If no zone indicator lights, the codepad is set up incorrectly or an incorrect codepad
is used.
Press [AWAY] to exit from this mode.
Installation Guide
Control Panel
Bosch Security Systems, Inc.