Preparing for Installation
• No. 1 Phillips screwdriver.
• Crimping tool to crimp the grounding wire to the grounding lug.
• Wire-stripping tool to remove the insulation from the grounding wire.
SUMMARY STEPS
1. Use a wire-stripping tool to remove approximately 0.75 inches (19 mm) of the covering from the end of
the grounding wire.
2. Insert the stripped end of the grounding wire into the open end of the right-angled grounding lug.
3. Crimp the grounding wire in the barrel of the grounding lug. Verify that the ground wire is securely
attached to the ground lug.
4. Secure the grounding lug to the system ground connector with two M4 screws. Ensure that the grounding
lug and the grounding wire do not interfere with other switch hardware or rack equipment.
5. Prepare the other end of the grounding wire, and connect it to an appropriate grounding point in your site
to ensure adequate earth ground for the switch.
Establishing System Ground
Catalyst 6800 Ethernet Module Installation Guide
19