Step 9
Make sure the ejector levers are fully closed and then tighten the two captive installation screws on the module.
Figure 11: Closing Ejector Levers in the Chassis Slot
1
Ejector levers fully closed and flush with the
module faceplate
Step 10
Verify that the module STATUS LED is lit.
Periodically check the STATUS LED color:
• If the STATUS LED changes from orange to green, the module has successfully completed the boot process and
is now online.
• If the STATUS LED remains orange or turns red, the module has not successfully completed the boot process and
may have encountered an error. For more information about the orange or red STATUS LED states, see Appendix
B.
What to Do Next
1 Install switching-module filler plates (Cisco part numbers SLOTBLANK-09 or WS-X6K-SLOT-CVR-E)
in any empty slots to maintain consistent airflow through the switch chassis.
2 Verify module installation.
Related Topics
C6800-48P-TX and C6800-48P-TX-XL Ethernet Modules, on page 1
C6800-48P-TX and C6800-48P-TX-XL Specifications, on page 37
Ethernet Module LEDs, on page 45
Example: show module Command Output for C6800-48P-TX-XL , on page 34
C6800-48P-SFP and C6800-48P-SFP-XL Ethernet Modules, on page 4
C6800-48P-SFP and C6800-48P-SFP-XL Module Specifications, on page 38
Ethernet Module LEDs, on page 45
Example: show module Command Output for C6800-48P-SFP , on page 35
C6800-8P10G and C6800-8P10G-XL Ethernet Modules, on page 6
C6800-8P10G and C6800-8P10G-XL Module Specifications, on page 40
Ethernet Module LEDs, on page 45
C6800-16P10G and C6800-16P10G-XL Ethernet Modules, on page 10
Installing an Ethernet Switching Module
-
Catalyst 6800 Ethernet Module Installation Guide
29

Advertisement

Table of Contents
loading

Table of Contents