Chapter 5
Troubleshooting the Cisco RPS
Fan Failure
OL-3654-01
Error Messages on Cisco 2600 Series and Cisco 3620, Cisco 3640, and Cisco 3725 Routers
SNMP Trap Issued Upon Correction of Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
LED status:
FAN LED is amber.
Console Error Message:
When an external device console screen displays the Cisco IOS software
•
prompt (
routername>
System detected Redundant Power Supply THERMAL FAIL condition.
The Cisco IOS software checks the condition once every 30 seconds. If the
condition still exists, the error message reappears.
When an external device console monitor screen displays the ROMMON
•
prompt (
rommon#>
*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY THERMAL BIT IS ASSERTED.
Error Description:
One of the Cisco RPS fans has failed. The remaining fans switch to full speed to
keep the Cisco RPS cool.
SNMP Trap Issued Upon Error:
ciscoEnvMonRedundantSupplyNotification is generated.
The varbinds included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState.
The value of ciscoEnvMonSupplyState is a warning.
Cisco Redundant Power System Hardware Installation Guide
or
)
routername#
)
5-9