Item
Condition
K4 type
1. Sensitivity
Adj item [SENS]
Adjustment Adjust [∗∗∗]
f
L
.
[S
E N S]
2. BPF
(PANEL TEST MODE)
CH-Sig 2-1
Tra-G setting -40dBm
CH-Sig 1-1
CH-Sig 3-1
3. Sensitivity
[Panel Test Mode]
Check
1) CH-Sig:1-1
SSG OUT
Wide:-118dBm (0.28µV)
(MOD:1kHz / ±3kHz)
Narrow:-116dBm (0.35µV)
(MOD:1kHz / ±1.5kHz)
4. Squelch (Open) 1) Adj item [SQL3]
Adjust
Adjust [∗∗∗]
[Wide]
SSG OUT
Wide:-123dBm
[Narrow]
2) Adj item [SQL3.]
Adjust [∗∗∗]
SSG OUT
Narrow:-126dBm
5. Squelch(Tight) 1) Adj item [SQL9]
Adjust
Adjust [∗∗∗]
[Narrow]
2) Adj item [SQL9.]
SSG OUT:-115dBm (0.4µV)
6. Squelch
[Panel Test Mode]
Check
1) CH-Sig:1-1
SQ Level : [SQL5]
SSG OUT:
-118dBm (0.28µV)
2) SSG OUT:OFF
ADJUSTMENT
Measurement
Test equipment
DVM
f
f
c
H
.
.
.
.
.
.
. .
[S
E
N
S]
[S
E
N
S
]
Tracking generator
spectrum analyzer
Fig. 1
SSG
AF VTVM
Oscilloscope
Adjustment
Terminal
Parts
Encoder knob
ANT
TC301, TC302,
TC303
BPF
ANT
TK-372G
Specifications/
Remark
Method
.
f
: ([S
E N S]) : [55]
L
.
.
.
f
: (S
E
N
S) : [125]
C
.
.
.
. .
f
: (S
E
N
S
) : [190]
H
Adjust wave form
to figure 1.(f
)
L
Check wave form to figure 2.(f
)
C
Check wave form to figure 2.(f
)
H
Fig. 2
Check
12dB SINAD or
more
Encoder
Adjust to the
knob
squelch
squelch.
threshold point
Adjust to the
squelch
threshold point
Check
Squelch must
be opened.
Squelch must
be closed.