Heat Pump Control — Electric Backup (Setup Functions 24-25):
Heat Pump Control — Fossil Fuel Backup (Setup Function 18):
Note: If temperature is not reached in a reasonable time, set the upstage to furnace timer
(function 21). After the designated time, the compressor will turn off and the system will switch to
back up heat.
OPTION 0: NO DROOP CONTROL
COMPRESSOR AND
FAN ONLY
40
FOSSIL FUEL
BACKUP HEAT ONLY
1
IF ROOM TEMPERATURE DROPS (EXCEEDS DROOP SETTING AT FUNCTION 20), COMPRESSOR IS DEACTIVATED. FOSSIL FUEL
BACKUP HEAT IS ACTIVATED AFTER 3 MINUTE DELAY.
**
FOR GEOTHERMAL HEAT PUMPS, THE BALANCE POINT CAN BE DISABLED AT SETUP FUNCTION 24.
Comfort/Economy — Setup Function
If you choose Comfort, auxiliary heat will respond quickly to meet the temperature setpoint. If you
choose Economy, the system will wait longer. Auxiliary heat will be activated only if the setpoint is
not reached within a reasonable time.
Settings & options (factory default in bold)
52
Thermostat
1 Basement
2 Bathroom
3 Bathroom 1
4 Bathroom 2
5 Bathroom 3
6 Bedroom
7 Bedroom 1
8 Bedroom 2
9 Bedroom 3
10 Bedroom 4
11 Boat House
12 Bonus Room
13 Computer Room 28 Kitchen 2
14 Den
15 Dining Room
0
Disconnect thermostat from wireless system
1
Thermostat is connected to wireless system
0
No reset
1
Reset installer options & program schedule to factory default settings
COMPRESSOR AND FAN ONLY
55
COMPRESSOR AND FAN OPERATE
1
40
ELECTRIC BACKUP HEAT AND FAN ONLY
1
IF THE COMPRESSOR CANNOT REACH OR MAINTAIN TEMPERATURE SETTING,
BOTH THE COMPRESSOR AND ELECTRIC BACKUP HEAT WILL OPERATE.
OPTION 1: DROOP CONTROL
COMPRESSOR AND
FAN OPERATE
1
BALANCE
40
FOSSIL FUEL
POINT **
BACKUP HEAT ONLY
Français : voir la page 21 • Español: vea la página 41
16 Exercise Room
17 Family Room
18 Fireplace
19 Foyer
20 Game Room
21 Garage
22 Great Room
23 Guest Room
24 Gym
25 Kid's Room
26 Kitchen
27 Kitchen 1
29 Laundry Room
AUXILIARY LOCKOUT
BALANCE
POINT **
26
(Not available when Setup Function
11
30 Library
31 Living Room
32 Lower Level
33 Master Bath
34 Master Bed
35 Media Room
36 Music Room
37 Nursery
38 Office
39 Office 1
40 Office 2
41 Pantry
42 Play Room
43 Pool Room
COMPRESSOR LOCKOUT
M28705
OPTION 2: DROOP CONTROL WITH AUX HEAT LOCKOUT
COMPRESSOR AND FAN ONLY
55
COMPRESSOR AND FAN OPERATE
1
40
FOSSIL FUEL BACKUP HEAT ONLY
44 Porch
45 Rec Room
46 Sewing Room
47 Spa
48 Storage Room
49 Studio
50 Sun Room
51 Theater
52 Thermostat
53 Upper Level
54 Utility Room
55 Walk In Closet
56 Wine Cellar
57 Workshop
AUXILIARY
LOCKOUT
BALANCE
POINT **
M28706
17
is set to 0):
69-2091EFS—07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents