Notes On Use Of Ddt Module - Hitachi SH7750 Hardware Manual

Sh7750 series superh risc engine
Hide thumbs Also See for SH7750:
Table of Contents

Advertisement

Four requests can be queued
CLK
4th
2nd
3rd
1st
A25–A0
D63–D0
RAS,
CAS, WE
ID1, ID0
Figure 14.52 Single Address Mode/Burst Mode/External Device → → → → External Bus Data
Transfer (Active Bank Address)/Direct Data Transfer Request to Channel 2
14.5.4

Notes on Use of DDT Module

1. Normal data transfer mode (channel 0)
Initial settings for channel 0 demand transfer must be DTR.ID = 00 and DTR.MD = 01, 10, or
11. In this case, only single address mode can be set for channel 0.
2. Normal data transfer mode (channels 1 to 3)
If a setting of DTR.ID = 01, 10, or 11 is made, DTR.MD will be ignored.
3. Handshake protocol using the data bus (valid on channel 0 only)
a. The handshake protocol using the data bus can be executed only on channel 0. (Set
DTR.ID = 00, DTR.MD = 00, DTR.SZ ≠ 101 or 110. Operation is not guaranteed if
settings of DTR.ID = 00, DTR.MD = 00, and DTR.SZ = 101 or 110 are made.)
b. If, during execution of the handshake protocol using the data bus for channel 0, a request is
input for one of channels 1 to 3, and after that DMA transfer is executed settings of
DTR.ID = 00, DTR.MD = 00, and DTR, SZ ≠ 101.110 are input in the handshake protocol
using the data bus, a transfer request will be asserted for channel 0.
Handshaking is necessary
to send additional requests
5th
CA
CA
D2
D3
D0
D0
D1
WT
WT
CA
D2
D1
D3
D0
D2
D1
WT
Must be ignored
(no request transmitted)
Rev. 6.0, 07/02, page 571 of 986
CA
D3
WT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh7750rSh7750s

Table of Contents