Instructions for Installation (cont'd)
Temperature-Pressure Relief Valve
AWARNING
AWARNING
At the time of manufacture this water heater was provid-
The temperature-pressure relief valve must be manu-
ed with a combination temperature-pressuresrelief valve
all), operated at least once a year. Caution should be
certified by a nationally recognizedtesting laboratory that
taken to ensure that (1) no one is in front of or
maintains periodic inspection of production of listed
around the outlet of the temperature-pressure relief
equipment or materials, as meeting the requirements for
va ved scharge
ne, and (2) the water manua y d s-
Relief Valves and Automatic Gas Shutoff Devices for Hot
ged will not cause any bodily injury or property
Water Supply Systems, and the latest edition of ANSI
age because the water may be extremely hot.
Z21.22 and the code requirements of ASME. If replaced,
Ier manually operating the valve, it fails to com-
the valve must meet the requirements of local codes, but
pletely reset and continues to release water, immedi-
not less than a combination temperature and pressure
ately close the cold water inlet to the water heater,
relief valve certified as meeting the requirements for
follow the draining
instructions,
and replace the
Relief Valves and Automatic Gas Shutoff Devices for Hot
temperature-pressure relief valve with a new one.
Water Supply Systems,ANSI Z21.22 by a nationally recog-
nized testing laboratory that maintains periodic inspecton
SHUTOFF
I of productionof listed equipment or materials.
_
VALVE
VALVE
The valve must be marked with a maximum set pressure
not to exceedthe marked hydrostaticworking pressureof
_---_-'-_
__
_
the water heater (150 Ibs./sq. in.) and a dischargecapacity
HOT
COLD
not lessthan the water heater input rate as shown on the
model rating plate. (Electric heaters - watts divided by
1000 x 3415 equal BTU/Hr.rate.)
Your local jurisdictional authority, while mandating the
f
use of a temperature-pressurerelief valve complying with
ANSI Z21.22 and ASME, may require a valve model differ-
_
--
ent from the one furnished with the water heater.
Compliancewith suchlocalrequirements must be satisfied
by the installer or end user of the water heater with a
locally prescribed temperature-pressure
relief valve
installed in the designatedopening in the water heater in
PRESSURE
placeof the factoryfurnishedvalve.
RELIEF V ALVE
For safe operation of the water heater, the relief valve
must not be removed from it's designated opening or
plugged.
_g)
The temperature-pressure relief valve must be installed
directly into the fitting of the water heater designated for
[]
the relief valve. Positionthe valve downward and provide I
tubing sothat any dischargewill exit only within 6 inchesI
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical
part. The discharge opening must not be blocked or'
reduced in size under any circumstances. E xcessive length,
over 30 feet, or use of more than four elbows can cause
restrictionand reducethe dischargecapacity of the valve.
No valve or other obstructionis to be placedbetween the
6"AIRGAP
relief valve and the tank. Do not connect tubing directlyto
B
dischargedrain unlessa 6 air gap is provided. To prevent
--
m
bodily injury, hazard to life, or property damage, the relief
FLOOR DRAIN
valve must be allowed to discharge water in quantities
should circumstances demand. If the dischargepipe is not
connected to a drain or other suitable means, the water
RELIEF
VALVE
OPENING
flow may causeproperty damage.
Atthetime ofmanufacture,
this water heater was provided with a combination
The DischargePipe:
temperature-pressure
relief valve l isted a s complying
with thestandard
forrelief
• Must notbe smaller in size than the outlet pipe size of
valves a nd a_oma_.ic gas shut-off devices for hotwater
supp}y
systems, AnSI
the valve, or have any reducing couplings or other
z21.22. Forsafe operation ofthewater heater, therelief v alve m ust n otbe
removed
from its designated
point ofinstallation
orplugged.
restrictions.
Your l ocal u risdictional
authority,
while mandating
theuse of a temperature-
. Must not be plugged or blocked,
pressure
relief v alve c omplying
with Ansi Z 21.22 and ASME, may require avalve
• Must be of material listed for hot water distribution,
model different from the one furnished
with thewater heater.
• Must be installed so as to allow complete drainage of
Compliance
with such local r equirements
must b esatisfied bytheinstaller or
enduser o fthewater heater witha locally prescribed
temperature-pressure
both the temperature-pressure relief valve, and the dis-
relief valve i nstalled inthedesignated
opening inthewater heater.
charge pipe.
See manual heading -"Temperature-Pressure
Relief Valves" forinstallation
and
• Must terminate at an adequate drain,
maintenance
ofrelief valve, discharge
line, and other safety precautions.
• Must not have any valve between the relief valve and
tank.
15