Instructions for Installation (cont'd)
Water Piping
AWARNING
1. Look at the top cover of the water heater. The water outlet
HOTrER WATER CAN SCALD: Water
heaters
are
is marked hot. Connect the hot water pipe to the hot
intended to produce hot water. Water heated to a
water outlet on the water heater.
temperature
which will satisfy clothes washing, dish
washing,
and other
sanitizing
needs
can scald
and
2. Look at the top cover of the water heater. The cold water
permanently
injure you upon contact. Some people
are more likely to be permanently
injured by hot
inlet is marked cold. Connect the cold water pipe to the
water than others. These include the elderly, chil-
cold water inlet of the water heater.
dren,
the
infirm,
or physically/mentally
handi-
capped. If anyone using hot water in your home fits
NOTE: This water heater is super insulated to minimize
into one of these groups or if there is a local code or
state law requiring a certain temperature
water at
heat loss from the tank. Further reduction in heat loss
the hot water tap, then you must take special pre-
can be accomplished by insulating the hot water lines
cautions. In addition to usinc_the lowest possible
from the water heater.
temperature
setting that satisfies your hot water
needs, a means such as a mixing valve, should be
used at the hot water taps used by these people or
at the water
heater. Mixing valves are available at
_alumbing supply or hardware stores. Follow manu-
cturers instructions for installation
of the valves.
Before changing the factory setting on the thermo-
THREADED T O
star, read the "Temperature
Regulation" section in
SWEAT COUPLING
this manual.
_
SHUTOFF
VALVE
hswtr
halo o cedoa
tems or component(s)
used with a non-potable water heating
_
_
appliance.
HOTOUTLET
I I
S"_
I
I_
]_
COLD
INLET
TO HOUSE
WATER LINE
If a water heater is installed in a closed water supply system;
such as one having a back-flow preventer, check valve, water
1_
[_
_.._
meter with a check valve, etc.., in the cold water supply;
means shall be provided to control thermal expansion.
Contact the local utility or call Maytag Customer Service
314"THREADED--
--
314"THREADED
Center at 1-800-788-8899
for an authorized installer on how
COUPLING
COUPLING
to control this situation.
1"ON 73 GAL.
1" ON 73 GAL.
NOTE: To protect against untimely corrosion of hot and
cold water fittings, it is strongly recommended that di-elec-
_
_
TEMPERATURE-
tric unions or couplings be installed on this water heater
PRESSURE
RELIEF
VALVE
when connected to copper pipe.
NOTE: The secondary anode rod/hot oudet nipple and the
*---
DISCHARGE P IPE
cold inlet nipple are packaged separately with the water
__
(Do not cap
heater. 73 gallon models have hot outlet and cold inlet
_
or plug)
nipples only. The above parts must be installed in the
i_
appropriate HOT and COLD water connection locations,
f_l
The illustration shows the attachment of the water piping to
_
_]'l
I
the water heater. The water heater is equipped with 3/4inch
water connections for 30, 40 and 50 gallon models and 1 inch
6" AIRGAP
water connections on 73 gallon models.
_
..
NOTE: Ifusing copper tubing, solder tubing to an adapter
before attaching the adaptor to the cold water inlet connection.
FLOOR DRAIN
Do not solder the cold water supply line direcdy to the cold
-.,ater inlet. It will harm the dip tube and damage the tank.
14