WHEN INSTALLING THIS PRODUCT...
1. Read these instructions carefully. Failure to follow
them could cause a hazardous condition.
2. Installer must be a trained experienced service technician.
3. After installation is complete, check out product op-
eration as provided in these instructions.
IMPORTANT: An incorrectly leveled subbase will cause
the temperature control to deviate from setpoint. It is
not a calibration problem.
CAUTION
1. Disconnect power supply to prevent electrical
shock or equipment damage.
2. To prevent interference with the thermostat link-
age, keep wire length to a minimum and run wires
as close as possible to the subbase.
3. Do not overtighten thermostat captive mounting
screws because damage to subbase threads can result.
4. Do not short across coil terminals on relay. This
can burn out the thermostat heat anticipator.
LOCATION
Locate thermostat about 5 ft [1.5m] above the floor in an
area with good air circulation at average temperature.
Do not mount the thermostat where it may be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from the sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall
behind the thermostat.
Run wires from the heating, cooling or heating/cooling
equipment to the new thermostat location.
Refer to the Typical Wiring Diagrams section to deter-
mine the number of wires required for your application.
UNPACK THERMOSTAT
Handle your new thermostat carefully; rough handling
may interfere with its accuracy. Before unpacking, refer to
Fig. 1.
Fig. 2—Mounting wallplate or subbase to wall.
3 SCREW HOLES
WITH PLASTIC
ANCHORS
FAN
ON
HEATING/COOLING SUBBASE
69-0642—1

Installation

O
B
R
W
G
Y
COOL
AUTO
HEAT
OFF
M1552A
Remove and discard the shipping wrap.
IMPORTANT: Save package of screws and instructions
for the homeowner.
Remove the thermostat cover by lifting from the bottom.
Set aside cover until needed later.
Carefully remove the material protecting the mercury
switch bulb.
Loosen two captive mounting screws and separate
wallplate (if provided) from back of thermostat base.
Fig. 1—Unpack thermostat.
CAPTIVE MOUNTING
SCREWS
1
LIFT
COVER
THERMOSTAT BASE
MOUNT WALLPLATE OR SUBBASE
Wall Mounting (Fig. 2)
Hold the wallplate or subbase in position on wall (Fig. 2).
Mark holes on the wall for anchors. Use spirit level to
make sure the wallplate or subbase is level.
Drill 3/16-in. holes, and gently tap anchors into holes
until flush with the wall.
Pull wires through the large wiring hole in the wallplate or
subbase.
Loosely fasten the wallplate or subbase to the wall with
the three screws. Do not completely tighten the screws.
Carefully level the wallplate or subbase (Fig. 3), and
firmly tighten the screws.
3 SCREW HOLES
WITH PLASTIC
ANCHORS
WALLPLATE
2
THERMOSTAT
COVER
35
30
2 0
REMOVE
PACKING
MATERIAL
M8673
M1815