Fig. 7—Insert timer batteries.
BATTERY LOCATION FOR
(2) AAA BATTERIES;
INSTALL WITH POSITIVE
ENDS UP
SET TIMER
Adjust the timer by moving the knob clockwise
Do not reverse the knob.
When time is correctly set, the time indicator arrow
(triangle shape) points to the correct time and the corre-
sponding daytime (light) or nighttime (dark) portion of the
program dial (Fig. 8).
SET HEAT ANTICIPATOR
Adjust the heat anticipator lever to match the current
rating of the primary control for the proper cycle rate (Fig. 9).
Adjustable anticipation must be set for total current of heat
and fan control.
The current rating is usually stamped on the control or
valve (Fig. 10), or a setting may be given in the device
instructions.
If no current rating or heat anticipator setting is given,
measure the current with an ammeter. Proceed with the
following steps.
Remove the thermostat from the wallplate or subbase.
Connect an ac ammeter of appropriate range (about 0A to
2A) between the R and W terminals on the wallplate or
subbase, except for electric heat and heat pump systems.
Fig. 10—Current rating of primary control.
SHOWS
VOLTAGE
RATING
V8043E 1004 4
24V 50/60CY
SHOWS
.32 AMP @ 60CY
ANTICIPATOR
SETTING
ZONE VALVE
Fig. 8—Set timer.
M8585
.
Let the system operate for one minute.
Adjust the heat anticipator lever to match the number that
reads on the ammeter.
Fig. 9—Adjust heat anticipator.
SHOWS
VOLTAGE
RATING
24 Vac 50/60 Hz
0.4 AMP
FROM MAIN
FUEL SUPPLY
TYPICAL GAS VALVE
5
PROGRAM DIAL
ANTICIPATOR
SCALEPLATE
ANTICIPATOR
SETTING LEVER
OIL BURNER CONTROL
SHOWS
CURRENT
DRAW
TO
BURNER
SHOWS
ANTICIPATOR
SETTING
PROGRAM
PIN (6)
TIMER
SETTING
KNOB
TIME
INDICATOR
ARROW
M821A
M7317
SHOWS LOW
VOLTAGE
T
T
F
F
M6116A
69-0642—1