Trigger Commands; Resetting The Standard Product Defaults - Honeywell 3800g User Manual

General purpose handheld linear imager
Hide thumbs Also See for 3800g:
Table of Contents

Advertisement

Trigger Commands

You can activate and deactivate the imager with serial trigger commands. First,
the imager must be put in Manual/Serial Trigger Mode either by scanning the
Manual/Serial Trigger Mode bar code
(page
3-3), or by sending the Manual/
Serial Menu Command
(page
11-8). Once the imager is in serial trigger mode,
the trigger is activated and deactivated by sending the following commands:
Activate:SYN T CR
Deactivate:SYN U CR
The imager scans until a bar code has been read, until the deactivate command
is sent, or until the serial time-out has been reached (see
Read Time-Out
on
page 3-3 for a description, and the serial command on
page
11-8).

Resetting the Standard Product Defaults

If you aren't sure what programming options are in your imager, or you've
changed some options and want the factory settings restored, scan the Stan-
dard Product Default Settings bar code below.
Standard Product Default Settings
The chart on the following pages lists the factory default settings for each of the
menu commands (indicated by an asterisk (*) on the programming pages).
11 - 4
3800g/3800gHD/3800gPDF User's Guide

Advertisement

Table of Contents
loading

Table of Contents