ELECTRIC
DRYER
ELECTRICAL
CONNECTIONS
Connecting
4-Wire
Connection:
Direct
Wire
Connecting
Ground and Neutral Wires (cont.)
Connecting
Remaining Wires
2. Connect ground and neutral wire to center terminal block.
Connecting
Direct Wire Ground
4. Connect remaining wires to outer terminal block.
3. Connect ground wire (green or bare) with external ground
connector screw.
Connecting
3-Wire
Connection:
Direct
Wire
Use where local codes permit connecting
cabinet=ground
conductor
to neutral wire.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer can be moved if needed.
Strip 31/2"(89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of
wires into a hook shape.
2. Connect neutral wire to center terminal block.
Connecting
Neutral Wire
1. Loosen or remove center terminal block screw.
3. Connect remaining wires to outer terminal block.
26