Installation
Instructions
CONNECT DUCTWORK
• Install ductwork, making connections in direction
of airflow as illustrated.
• Push duct over the exhaust outlet until it reaches
the duct stops.
• Secure joints in ductwork with sheetmetal screws.
• Wrap all duct joints with duct tape for an airtight seal.
• Use duct tape to seal the flange connection.
CAUTION:
Do not use sheet metal screws at
the hood flange connection.
Doing so will prevent proper
damper operations.
Seal connection
with tape only.
PRUDENCE
II ne faut pas utiliser de vis autoraurdeuses 0 la connexion
du collet de la hotte. Ceci emp6cherait le ban
fonctionnement du registre. N'utiliser que du ruban adh6sif
pour assurer 1'6tanch6it6 du raccord.
Duct Tape
OverSeam
Ouct Stops
_.
.... /
....
I
CONNECT ELECTRICAL
Verify that power is turned offet the source.
WARNING:
,f house wiring is not 2-wire with a
ground wire, a ground must be provided by the installer.
When house wiring is aluminum, be sure to use U.L.ap-
proved anti-oxidant compound and aluminum-to-copper
connectors.
AVERTISSEMENT
Si la maison n'est pas cabl6e avec deux ills et un fil de
terre, I'installateur doit installer un fil de terre. Quand les ills
sont en aluminium, il faut prendre soin d'utiliser des con-
necteurs aluminium 5 cuivre avec une pete antioxydante
approuv6e par UL.
• Insert house wiring through strain relief and tighten.
• Connect white leads to branch circuit white lead.
• Connect black leads to branch circuit black lead.
• Connect green/yellow leads to branch circuit green lead
or bore ground lead.
• Secure all connections with wire nuts on each electrical
connector.
• Push wires into junction box and replace cover. Be sure
wires are not pinched.
INSTALL DUCT COVERS
Mounting
Screws
• Place the decorative duct
covers on top of the hood.
• Insert the lower portion
of the duct cover into the
impressions on the top of
the hood.
Bottom
•Notches
• Extend the inner duct upwards to the ceiling bracket.
• Secure the duct cover to the bracket with the 2 small
Phillips screws provided.