    Spec Sheet Cisco UCS B22 M3 Blade Server ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 A.11 9, 2013 UGUST CISCO...
  • Page 2: Table Of Contents

    6 ORDER A TRUSTED PLATFORM MODULE ......20 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS ....21 STEP 8 ORDER OPTIONAL INTERNAL USB 2.0 DRIVE .
  • Page 3: Overview

    OVERVIEW OVERVIEW The Cisco® UCS B22 M3 Blade Server delivers a balanced price/performance feature set to address quick deployment of scalable IT infrastructure and Web 2.0 applications. The Cisco UCS B22 M3 harnesses the power of the latest Intel® Xeon® processor E5-2400 product family with expandability to 384 GB of RAM (using 32 GB DIMMs), 2 hot-plug drives, and 2 PCIe mezzanine adapter slots for up to 80 Gbps throughput.
  • Page 4: Detailed Views

    DETAILED VIEWS DETAILED VIEWS Blade Server Front View Figure 2 is a detailed front view of the Cisco UCS B22 M3 Blade Server. Figure 2 Blade Server Front View UCS B22 M3 Asset pull handle Network link status LED (a blank asset tag is provided on which...
  • Page 5: Base Server Standard Capabilities And Features

    CONFIGURING the SERVER on page Table 1 Capabilities and Features Capability/Feature Description Chassis The UCS B22 M3 Blade Server mounts in a Cisco UCS 5100 series blade server chassis One or two Intel® E5-2400 series processor family CPUs Chipset Intel® C600 series chipset...
  • Page 6 • One console connector (see ORDER OPTIONAL KVM LOCAL I/O CABLE* on page Power subsystem Integrated in the Cisco UCS 5100 series blade server chassis Fans Integrated in the Cisco UCS 5100 series blade server chassis Integrated management The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI...
  • Page 7: Configuring The Server

    CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B22 M3 Blade Server: STEP 1 VERIFY SERVER SKU, page 8 ■ STEP 2 CHOOSE CPU(S), page 9 ■ STEP 3 CHOOSE MEMORY, page 11 ■...
  • Page 8: Step 1 Verify Server Sku

    UCSB-B22-M3 UCS B22 M3 Blade Server without CPU, memory, HDD, VIC 1240 adapter, or mezzanine adapters The base Cisco UCS B22 M3 blade server does not include the following components. They are to be selected during product ordering: CPU(s) ■...
  • Page 9: Step 2 Choose Cpu(S)

    ■ Cache sizes of 10, 15, or 20 MB ■ Select CPUs The supported Intel Xeon E5-2400 series family CPUs on the UCS B22 M3 are listed in Table Table 3 Supported Intel CPUs: E5-2400 Series Processor Family CPUs Clock...
  • Page 10 B22 M3 configured with 1 CPU or 2 CPUs. The VIC 1240 adapter is supported for 1- or 2-CPU configurations. ■ Cisco, Emulex, or QLogic I/O adapters or Cisco UCS Storage Accelerators are supported only ■ for 2-CPU configurations.
  • Page 11: Step 3 Choose Memory

    Memory is organized with three memory channels per CPU, with up to two DIMMs per ■ channel (DPC), as shown in Figure 3. Maximum memory capacity is 384 GB (with 32 GB DIMMs). Figure 3 UCS B22 M3 Memory Organization Cisco UCS B22 M3 Blade Server...
  • Page 12 DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data. The supported memory DIMMs in the UCS B22 M3 are listed in Table Table 4 Supported DDR3 DIMMs and Memory Mirroring Option...
  • Page 13 1600-MHz speeds provided: — The DIMMs are 1600-MHz devices — The CPUs chosen support 1600-MHz operation For more information regarding memory, see DIMM and CPU Layout on page 34 DIMM Population on page Cisco UCS B22 M3 Blade Server...
  • Page 14: Step 4 Choose Hard Disk Drives Or Solid State Drives (Optional)

    CONFIGURING the SERVER STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL) The UCS B22 M3 can be ordered with or without drives. The standard disk drive features are: 2.5-inch small form factor ■ Hot-pluggable sled mounted ■...
  • Page 15 Select two identical drives from Table 6. There is no support for mixing of drive types or ■ capacities. Caveats If you select two drives, they must be identical in type and capacity. ■ Cisco UCS B22 M3 Blade Server...
  • Page 16: Step 5 Choose Adapters

    The adapter offerings are: Cisco Adapters: Virtual Interface Cards (VICs) ■ Cisco developed Virtual Interface Cards (VICs) to provide flexibility to create multiple NIC and HBA devices. The VICs also support adapter Fabric Extender and Virtual Machine Fabric Extender technologies.
  • Page 17 CONFIGURING the SERVER Choose a Mezzanine Adapter The supported mezzanine adapters in the UCS B22 M3 are listed in Table Table 7 Supported Mezzanine Adapters Product ID (PID) PID Description Connector Virtual Interface Cards (VICs) UCSB-MLOM-40G-01 Cisco UCS VIC 1240 modular LOM for M3 blade servers. Plugs into Adapter 1 adapter slot 1 only.
  • Page 18 Figure 16 on page 47 2208XP VIC 1240 6 x 10 Gb Figure 17 on page 48 Emulex or QLogic I/O adapter 2208XP VIC 1240 VIC 1280 8 x 10 Gb Figure 18 on page 48 Cisco UCS B22 M3 Blade Server...
  • Page 19 Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Caveats If a VIC 1240 adapter is not installed (2-CPU configuration only), you must choose a Cisco, ■ Emulex, or QLogic I/O adapter to be installed in adapter 2 slot (see also...
  • Page 20: Step 6 Order A Trusted Platform Module

    Table 11 Trusted Platform Module Product ID (PID) PID Description UCSX-TPM1-001 Trusted Platform Module for UCS NOTE: The module used in this server conforms to TPM v1.3, as defined by the Trusted Computing Group (TCG). Cisco UCS B22 M3 Blade Server...
  • Page 21: Step 7 Order Cisco Flexible Flash Secure Digital Cards

    16 GB SD Card module for UCS Servers NOTE: The SD card transfer rates are: Sequential reads: 23 MB/s ■ Sequential writes: 20 MB/s ■ Supported Configurations (1) Select one or two Cisco Flexible Flash secure digital card Cisco UCS B22 M3 Blade Server...
  • Page 22: Step 8 Order Optional Internal Usb 2.0 Drive

    Figure 6 on page 33 for the location of the USB connector. NOTE: When the Cisco 4GB USB key is purchased with a server, it is pre-installed into the internal USB port and held firmly in place with a clip to protect it from shock and vibration during shipment and transportation.
  • Page 23: Step 9 Choose Operating System And Value-Added Software

    Windows Server 2012 Standard (2 CPU/2 VMs) MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco Svc SUSE Linux Enterprise Server...
  • Page 24 VMware vCenter 5 Server Standard, 1 yr support required  VMW-VC5-STD-2A VMware vCenter 5 Server Standard, 2 yr support required  VMW-VC5-STD-3A VMware vCenter 5 Server Standard, 3 yr support required  VMW-VC5-STD-4A VMware vCenter 5 Server Standard, 4 yr support required  Cisco UCS B22 M3 Blade Server...
  • Page 25 Product ID (PID) VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required  UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers  NOTE: For additional information, see OS/hypervisor support matrix at the following link: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.h Cisco UCS B22 M3 Blade Server...
  • Page 26: Step 10 Choose Operating System Media Kit

    Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media MSWS-12-DC2S-RM Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media Cisco UCS B22 M3 Blade Server...
  • Page 27: Step 11 Choose Service And Support Level

    SMARTnet for UCS For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
  • Page 28 For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required.
  • Page 29 CONFIGURING the SERVER Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. Table Table 18 Partner Support Service for UCS Service Product ID (PID)
  • Page 30 With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
  • Page 31 UCS HW+DR UCWD5 8x5xNBD Onsite CON-UCWD5-B22M3 Retention For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS B22 M3 Blade Server...
  • Page 32: Order Optional Kvm Local I/O Cable

    KVM Local I/O Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB connector (for a mouse and keyboard) NOTE: *The blade chassis ships with the KVM local I/O cable. Cisco UCS B22 M3 Blade Server...
  • Page 33: Supplemental Material

    (adapter not shown) Notes 1. A USB device installed in this connector must have sufficient clearance to easily slide in and out. The Cisco USB device clearance is 0.950 inches (24.1 mm), which is a sufficient amount of clearance. Cisco UCS B22 M3 Blade Server...
  • Page 34: Dimm And Cpu Layout

    The DIMM and CPU physical layout is shown in Figure 8. The 6 DIMM slots at the left are controlled by CPU 1 and the 6 DIMM slots on the right are controlled by CPU 2. Cisco UCS B22 M3 Blade Server...
  • Page 35 SUPPLEMENTAL MATERIAL Figure 8 DIMM and CPU Layout CPU 1 CPU 2 Channels B-D for CPU 1 Channels F-H for CPU 2 Cisco UCS B22 M3 Blade Server...
  • Page 36: Dimm Population

    20/28 none none none none none none none none none none none none none none none none 32/48 8/16 8/16 none none none none none none 28/36 8/16 none none none none none none Cisco UCS B22 M3 Blade Server...
  • Page 37 8/16 none none none none 48/80 8/16 8/16 none none 8/16 8/16 none none 40/56 8/16 none none 8/16 none none none none none none 64/96 8/16 8/16 8/16 8/16 56/72 8/16 8/16 Cisco UCS B22 M3 Blade Server...
  • Page 38: Upgrade And Servicing-Related Parts

    Similarly, a blade server blanking panel (N20-CBLKB1=) must be installed if you remove a half-width blade server (such as a UCS B22 M3 server) from a blade server chassis. These panels are required to maintain system temperatures at safe operating levels, and to keep dust away from system components.
  • Page 39: Cpu Removal And Installation ("Pick N Place") Tool Set

    Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level. The UCS B22 M3 server comes shipped with two identical air baffles covering the DIMM socket areas of the server. These baffles must always remain installed during server operation. The Air Baffle Replacement Kit includes the two (identical) air baffles needed for one UCS B22 M3 server.
  • Page 40: Cpu Heat Sink Cleaning Kit

    The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process. Instructions for cleaning are found at the following link: http://www.cisco.com/en/US/docs/unified_computing/ucs/hw/chassis/install/b22.html#wp1010281 NOTE: When you purchase a spare CPU, the CPU cleaning kit is included. Cisco UCS B22 M3 Blade Server...
  • Page 41: Network Connectivity

    This section explains how the UCS B22 M3 server connects to Fabric Interconnects using the network I/O adapters in the UCS B22 M3 blade server and the Fabric Extender modules in the UCS 5108 blade server chassis. The UCS B22 M3 server plugs into the front of the UCS 5108 blade server chassis. The Fabric Extender modules plug into the back of the UCS 5108 series blade server chassis.
  • Page 42: Vic 1240 Adapter

    VIC 1240 Adapter The only adapter that can be plugged in to the VIC 1240 slot is the VIC 1240, a Cisco-designed PCIe-based adapter that in the UCS B22 M3 server provides up to four (depending on the Fabric Extender option chosen) 10 Gigabit Data Center Ethernet (DCE) network interfaces.
  • Page 43: Mezzanine Adapters

    Cisco UCS Storage Accelerators (such as memory cards) ■ NOTE: In a B22 M3 configured with 2 CPUs, if a UCS B22 M3 blade server does not have a VIC 1240 installed, the mezzanine slot is required to have a network adapter installed.
  • Page 44: B22 M3 Configured With 1 Cpu

    Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second-generation Fabric Extender, and shares the same form factor as the current UCS 2100 series. The 2208XP is backwards compatible with the UCS 5108 Blade serve chassis.
  • Page 45: Connectivity Using The Cisco Ucs 2104Xp Fabric Extender

    The option shown in Figure 13 demonstrates how a 1-CPU server is connected to the Cisco UCS 2104XP. One port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B. The result is 10 Gbps of bandwidth to each Fabric Extender.
  • Page 46: B22 M3 Configured With 2 Cpus

    ■ Figure 14, there is no VIC 1240 adapter installed. In this case, a Cisco, Emulex, or QLogic I/O adapter must be installed in the adapter 2 slot. Ports A and B of the mezzanine adapter connect to the Fabric Extenders, providing 10 Gbps per port.
  • Page 47 2208XP Fabric Extender B. The result is 20 Gbps of bandwidth to each Fabric Extender. The Cisco UCS Storage Accelerator adapter in the adapter 2 slot has no network connectivity. Figure 16 Option 3 - VIC 1240 to UCS 2208XP Fabric Extender (with Cisco UCS Storage Accelerator adapter) Cisco UCS B22 M3 Blade Server...
  • Page 48 2208XP Fabric Extender B. The VIC 1280 installed in the adapter 2 slot also channels two ports to each of the Fabric Extenders. The result is 40 Gbps of bandwidth to each Fabric Extender. Figure 18 Option 5 - VIC 1240 and VIC 1280 to UCS 2208XP Fabric Extender Cisco UCS B22 M3 Blade Server...
  • Page 49: Connectivity Using The Cisco Ucs 2204Xp Fabric Extender

    Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2208XP is a second-generation Fabric Extender, and shares the same form factor as the current UCS 2100 series. The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis.
  • Page 50 21, one port from the VIC 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B. The result is 10 Gbps of bandwidth to each Fabric Extender. The Cisco UCS Storage Accelerator adapter has no network connectivity.
  • Page 51 2204XP Fabric Extender B. The VIC 1280 installed in the adapter 2 slot also channels one port to each of the Fabric Extenders. The result is 20 Gbps of bandwidth to each Fabric Extender. Figure 23 Option 5 - VIC 1240 and VIC 1280 to UCS 2204XP Fabric Extender Cisco UCS B22 M3 Blade Server...
  • Page 52: Connectivity Using The Cisco Ucs 2104Xp Fabric Extender

    24, one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B. The result is 10 Gbps of bandwidth to each Fabric Extender. The Cisco UCS Storage Accelerator adapter located in the mezzanine connector acts as an independent device controlled by CPU 2 and has no network connectivity.
  • Page 53: Technical Specifications

    Fully configured server ■ (2 HDDs, 2 CPUs, VIC 1240 and mezzanine adapters both populated, all memory) = 14.98 lbs (6.79 kg) Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Cisco UCS B22 M3 Blade Server...
  • Page 54 TECHNICAL SPECIFICATIONS Cisco UCS B22 M3 Blade Server...