Cisco UCS B200 M3 Spec Sheet

Cisco UCS B200 M3 Spec Sheet

Ucs b200 m3 blade server
Hide thumbs Also See for UCS B200 M3:
Table of Contents

Advertisement

Cisco UCS B200 M3

Blade Server

C
S
ISCO
YSTEMS
170 W
T
D
.
EST
ASMAN
R
S
J
, CA, 95134
AN
OSE
.
.
WWW
CISCO
COM
P
H
UBLICATION
ISTORY
R
C.6
M
27, 2014
EV
AY
Spec Sheet

Advertisement

Table of Contents
loading

Summary of Contents for Cisco UCS B200 M3

  • Page 1: Blade Server

    Spec Sheet Cisco UCS B200 M3 Blade Server ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 27, 2014 CISCO...
  • Page 2: Table Of Contents

    6 ORDER A TRUSTED PLATFORM MODULE ......23 STEP 7 ORDER CISCO FLEXIBLE FLASH SECURE DIGITAL CARDS ....24 STEP 8 ORDER OPTIONAL INTERNAL USB 2.0 DRIVE .
  • Page 3: Overview

    The enterprise-class Cisco UCS B200 M3 blade server extends the capabilities of Cisco’s Unified Computing System portfolio in a half-width blade form factor. The Cisco UCS B200 M3 harnesses the power of the latest Intel® Xeon® E5-2600 v2 and E5-2600 series processor family CPUs with up to 768 GB of RAM (using 32 GB DIMMs), 2 drives, and up to 80 Gbs throughput connectivity.
  • Page 4: Detailed Views

    DETAILED VIEWS DETAILED VIEWS Blade Server Front View Figure 2 is a detailed front view of the Cisco UCS B200 M3 Blade Server. Figure 2 Blade Server Front View UCS B200 M3 Asset pull handle Network link status LED (a blank asset tag is provided on which...
  • Page 5: Base Server Standard Capabilities And Features

    Table 1 Capabilities and Features Capability/Feature Description Chassis The UCS B200 M3 Blade Server mounts in a Cisco UCS 5100 series blade server chassis One or two Intel® E5-2600 v2 or E5-2600 series processor family CPUs Chipset Intel® C600 series chipset...
  • Page 6 • One console connector (see ORDER OPTIONAL KVM LOCAL I/O CABLE* on page Power subsystem Integrated in the Cisco UCS 5100 series blade server chassis Fans Integrated in the Cisco UCS 5100 series blade server chassis Integrated management The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI...
  • Page 7: Configuring The Server

    CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 M3 Blade Server: STEP 1 VERIFY SERVER SKU, page 8 ■ STEP 2 CHOOSE CPU(S), page 9 ■ STEP 3 CHOOSE MEMORY, page 12 ■...
  • Page 8: Step 1 Verify Server Sku

    Description UCSB-B200-M3 UCS B200 M3 Blade Server w/o CPU, memory, HDD, VIC 1240 adapter, or mezzanine adapters The base Cisco UCS B200 M3 blade server does not include the following components. They must be selected during product ordering: CPUs ■...
  • Page 9: Step 2 Choose Cpu(S)

    E5-2620 v2 2.10 7.2 GT/s 1600 UCS-CPU-E52643B E5-2643 v2 3.50 8 GT/s 1866 UCS-CPU-E52650LB E5-2650L v2 1.70 8 GT/s 1600 UCS-CPU-E52630LB E5-2630L v2 2.40 7.2 GT/s 1600 UCS-CPU-E52609B E5-2609 v2 2.50 6.4 GT/s 1333 Cisco UCS B200 M3 Blade Server...
  • Page 10 The B200 M3 configured with 1 CPU provides limited network connectivity options. The ■ following restrictions apply: — A virtual interface card (VIC), the VIC 1240, must always be installed in the VIC 1240 mezzanine connector. Cisco UCS B200 M3 Blade Server...
  • Page 11 For optimal performance, select DIMMs with the highest clock speed for a given processor. ■ System speed is dependent on how many DIMMs are populated per channel. See Table 7 on ■ page 16 for details. Cisco UCS B200 M3 Blade Server...
  • Page 12: Step 3 Choose Memory

    Memory is organized with four memory channels per CPU, with up to three DIMMs per ■ channel (DPC), as shown in Figure 3. Maximum memory capacity is 768 GB (B200 M3 configured with 2 CPUs with 32 GB DIMMs). Figure 3 UCS B200 M3 Memory Organization Cisco UCS B200 M3 Blade Server...
  • Page 13 DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data. The supported memory DIMMs in the UCS B200 M3 are listed in Table Table 4 Supported DDR3 DIMMs and Memory Mirroring Option...
  • Page 14 4 DIMMs in Bank 1 (A1, B1, C1, D1) 4 DIMMs in Bank 3 (A2, B2, C2, D2) Notes... 1. Not recommended (for performance reasons) Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page ■ Cisco UCS B200 M3 Blade Server...
  • Page 15 Table 4 on page ■ NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server. Cisco UCS B200 M3 Blade Server...
  • Page 16 By default, starting with UCSM 2.0.4, DIMMs run in memory performance mode (1.5v) by ■ BIOS default, which yields faster memory speeds than when the BIOS is set for the memory to run in power-savings mode. Memory speed is dependent on factors such as: — CPU choice Cisco UCS B200 M3 Blade Server...
  • Page 17 (1.35 V) or performance mode (1.5 V). With 3 LRDIMMs populated per channel, memory can operate at 1.5 V or 1.35 V, depending ■ on the BIOS setting. For more information regarding memory, see CPUs and DIMMs on page Cisco UCS B200 M3 Blade Server...
  • Page 18: Step 4 Choose Hard Disk Drives Or Solid State Drives (Optional)

    CONFIGURING the SERVER STEP 4 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES (OPTIONAL) The UCS B200 M3 can be ordered with or without drives. The standard disk drive features are: 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted ■...
  • Page 19 Select two identical drives from Table 8. There is no support for mixing of drive types or ■ capacities. Caveats If you select two drives, they must be identical in type and capacity. ■ Cisco UCS B200 M3 Blade Server...
  • Page 20: Step 5 Choose Adapters

    The adapter offerings are: Cisco Virtual Interface Cards (VICs) ■ Cisco developed Virtual Interface Cards (VICs) to provide flexibility to create multiple NIC and HBA devices. The VICs also support adapter Fabric Extender and Virtual Machine Fabric Extender technologies. Converged Network Adapters (CNAs) ■...
  • Page 21 Mezzanine Expander Option UCSB-MLOM-PT-01 Cisco UCS Port Expander Card for VIC 1240. This is a hardware Mezzanine option to enable an additional 4 ports of the VIC 1240, bringing the total capability of the VIC 1240 to dual 4 x 10 GbE...
  • Page 22 Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Caveats If a VIC 1240 adapter is not installed, you must choose an Emulex or QLogic I/O adapter to ■ be installed in the mezzanine slot (see also NEBS Compliance on page Cisco UCS B200 M3 Blade Server...
  • Page 23: Step 6 Order A Trusted Platform Module

    Table 12 Trusted Platform Module Product ID (PID) PID Description UCSX-TPM1-001 Trusted Platform Module for UCS NOTE: The module used in this server conforms to TPM v1.2, as defined by the Trusted Computing Group (TCG). Cisco UCS B200 M3 Blade Server...
  • Page 24: Step 7 Order Cisco Flexible Flash Secure Digital Cards

    Table 13 Supported Configurations - Secure Digital Card(s) Product ID (PID) PID Description UCS-SD-16G 16GB SD Card module for UCS Servers Supported Configurations (1) Select one or two Cisco Flexible Flash secure digital cards Cisco UCS B200 M3 Blade Server...
  • Page 25: Step 8 Order Optional Internal Usb 2.0 Drive

    Figure 5 on page 36 for the location of the USB connector. NOTE: When the Cisco 4GB USB key is purchased with a server, it is pre-installed into the internal USB port and held firmly in place with a clip to protect it from shock and vibration during shipment and transportation.
  • Page 26: Step 9 Choose Operating System And Value-Added Software

    MSWS-12-ST2S Windows Server 2012 Standard (2 CPU/2 VMs) MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC SUSE SLES-SVR-2S-1G-1A SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd...
  • Page 27 VSG-VLEM-UCS-1 VSG License Paper Delivery (1 CPU) for bundles UCS Director CUIC-PHY-SERV-BM-U Cisco Cloupia Resource Lic - One Phy Server node bare metal CUIC-PHY-SERV-U Cisco Cloupia Resource Lic - One physical Server node CUIC-TERM Acceptance of Cisco Cloupia License Terms...
  • Page 28 VMware vCenter 5 Server Standard, 4 yr support required  VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required  UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers  NOTE: For additional information, see OS/hypervisor support matrix at the following link: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html Cisco UCS B200 M3 Blade Server...
  • Page 29: Step 10 Choose Operating System Media Kit

    RHEL 6 Recovery Media Only (Multilingual) SLES-11 SLES 11 media only (multilingual) MSWS-08R2-STHV-RM Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media MSWS-08R2-ENHV-RM Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media Cisco UCS B200 M3 Blade Server...
  • Page 30: Step 11 Choose Service And Support Level

    Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired...
  • Page 31 CONFIGURING the SERVER Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco Unified Computing Warranty Plus Service. You can choose from several levels of advanced parts replacement coverage, including onsite parts replacement in as little as four hours.
  • Page 32 CONFIGURING the SERVER Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. Table Table 19 Partner Support Service for UCS Service Product ID (PID)
  • Page 33 With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
  • Page 34 With Drive Onsite Retention UCWD7 24x7x4 Onsite CON-UCWD7-B200M3 For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS B200 M3 Blade Server...
  • Page 35: Order Optional Kvm Local I/O Cable

    KVM Local I/O Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB connector (for a mouse and keyboard) NOTE: *The blade chassis ships with the KVM local I/O cable. Cisco UCS B200 M3 Blade Server...
  • Page 36: Supplemental Material

    (mezzanine adapter not shown installed) Notes... 1. A USB device installed in this connector must have sufficient clearance to easily slide in and out. The Cisco USB device clearance is 0.950 inches (24.1 mm), which is a sufficient amount of clearance.
  • Page 37: Cpus And Dimms

    Bank 1 - A1, B1, C1, and D1 (black DIMM slots) — Bank 2 - A2, B2, C2, and D2 (white DIMM slots) CPU2: Channels E, F, G, and H ■ — Bank 0 - E0, F0, G0, and H0 (blue DIMM slots) Cisco UCS B200 M3 Blade Server...
  • Page 38 1 and the 12 DIMM slots on the right are controlled by CPU 2. Figure 7 DIMM and CPU Layout E0 E0 E1 E1 E2 E2 F0 F0 F1 F1 F2 F2 CPU 2 CPU 1 Channels A-D for CPU 1 Channels E-H for CPU 2 Cisco UCS B200 M3 Blade Server...
  • Page 39: Dimm Population Rules

    1. Although you can have different DIMM capacities in the same bank, this will result in less than optimal performance. For optimal performance, all DIMMs in the same bank should be identical. 2. Only 1866-, 1600-, and 1333-MHz DIMMs are currently available for the B200 M3 server. Cisco UCS B200 M3 Blade Server...
  • Page 40: Dimm Population Order

    E1, F1, G1, H1 A0, B0, C0, D0, E0, F0, G0, H0, A1, B1, C1, D1, E1, F1, G1, H1, A2, B2, C2, D2 E2, F2, G2, H2 Notes... 1. Not recommended (for performance reasons) Cisco UCS B200 M3 Blade Server...
  • Page 41: Recommended Memory Configuration

    — 1866 4x8 GB 4x4 GB — 4x8 GB 4x4 GB — 128 GB 4x8 GB 4x8 GB — 4x8 GB 4x8 GB — 1866 4x16 GB — — 4x16 GB — — 1866 Cisco UCS B200 M3 Blade Server...
  • Page 42 1600 32 GB 2x8 GB — — 2x8 GB — — 1600 64 GB 4x4 GB 4x4 GB — 4x4 GB 4x4 GB — 1600 4x8 GB — — 4x8 GB — — 1600 Cisco UCS B200 M3 Blade Server...
  • Page 43 4x32 GB 4x32 GB — 4x32 GB 4x32 GB — 1333 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1066 768 GB Notes... 1. Rows marked in yellow indicate best performance. Cisco UCS B200 M3 Blade Server...
  • Page 44: Additional Dimm Populations

    8 x 16 GB 128 GB 256 GB 4 x 32 GB 128 GB 4 x 32 GB 128 GB 256 GB 8 x 32 GB 256 GB 8 x 32 GB 256 GB 512 GB Cisco UCS B200 M3 Blade Server...
  • Page 45: Upgrade And Servicing-Related Parts

    Similarly, a blade server blanking panel (N20-CBLKB1=) must be installed if you remove a half-width blade server (such as a UCS B200 M3 server) from a blade server chassis. These panels are required to maintain system temperatures at safe operating levels, and to keep dust away from system components.
  • Page 46: Adding An Additional Cpu (With Cpu Heat Sink)

    Adding an Additional CPU (with CPU heat sink) All Cisco UCS two CPU socket-capable servers can be upgraded from having one to having two CPUs configured. You will need to order and install a heat sink when adding any additional CPU to a server.
  • Page 47: Air Baffle Replacement Kit

    Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level. The UCS B200 M3 server comes shipped with two identical air baffles covering the DIMM socket areas of the server. These baffles must always remain installed during server operation. The Air Baffle Replacement Kit includes the two (identical) air baffles needed for one UCS B200 M3 server.
  • Page 48: Nebs Compliance

    Up to two: 600 GB 10K RPM SAS drives A03-D600GA2 (1.2 TB maximum total capacity) Mezzanine Cards Cisco UCS VIC 1240 adapter for M3 blade servers UCSB-MLOM-40G-01 Cisco UCS Port Expander Card for VIC 1240 UCSB-MLOM-PT-01 Cisco UCS B200 M3 Blade Server...
  • Page 49: Network Connectivity

    This section explains how the UCS B200 M3 server connects to Fabric Interconnects using the network adapters in the UCS B200 M3 blade server and the Fabric Extender modules in the UCS 5108 blade server chassis. The UCS B200 M3 server plugs into the front of the UCS 5108 blade server chassis. The Fabric Extender modules plug into the back of the UCS 5108 series blade server chassis.
  • Page 50: Vic 1240 Adapter

    VIC 1240 Adapter The only adapter that can be plugged in to the VIC 1240 slot is the VIC 1240, a Cisco-designed PCIe based adapter that provides up to eight (depending on the Fabric Extender option chosen) 10 Gigabit Data Center Ethernet (DCE) network interfaces.
  • Page 51: Mezzanine Adapters

    Cisco Storage Accelerator adapters (such as Fusion-io and LSI cache cards) ■ NOTE: In a B200 M3 configured with 2 CPUs, if a UCS B200 M3 blade server does not have a VIC 1240 installed, the mezzanine slot is required to have a QLogic or Emulex I/O adapter installed to provide I/O connectivity.
  • Page 52: B200 M3 Configured With 1 Cpu

    2 CPUs, CPU 2 controls the slot). Therefore, the only adapter that can be placed in the mezzanine slot in a B200 M3 configured with 1 CPU is the Cisco UCS Port Expander Card for VIC 1240, and the VIC 1240 is always required to be installed in the VIC 1240 slot.
  • Page 53: Connectivity Using The Cisco Ucs 2204Xp Fabric Extender

    Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second-generation Fabric Extender, and shares the same form factor as the current UCS 2100 series. The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis.
  • Page 54 Fabric Extenders. The result is 20 Gbps of bandwidth to each Fabric Extender. Figure 13 Option 2 - VIC 1240 and Port Expander Card for VIC 1240 to UCS 2204XP Fabric Extender Cisco UCS B200 M3 Blade Server...
  • Page 55 Connectivity using the Cisco UCS 2104XP Fabric Extender The option shown in Figure 14 demonstrates how the UCS B200 M3 blade serves connects to a UCS 2104XP Fabric Extender. Figure 14, one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B.
  • Page 56: B200 M3 Configured With 2 Cpus

    Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second-generation Fabric Extender, and shares the same form factor as the current UCS 2100 series. The 2208XP is backwards compatible with the UCS 5108 Blade serve chassis.
  • Page 57 Fabric Extenders. The result is 30 Gbps of bandwidth to each Fabric Extender. Figure 17 Option 3 - VIC 1240 and Emulex or QLogic I/O Adapter to UCS 2208XP Fabric Extender Cisco UCS B200 M3 Blade Server...
  • Page 58 Port A and B of the mezzanine adapter connect to the Fabric Extenders, providing 10 Gbps per port. Figure 19 Option 5 - Emulex or QLogic I/O Adapter to UCS 2208XP Fabric Extender (no VIC 1240 adapter) Cisco UCS B200 M3 Blade Server...
  • Page 59 Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second-generation Fabric Extender, and shares the same form factor as the current UCS 2100 series. The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis.
  • Page 60 2204XP Fabric Extender B. The adapter installed in the mezzanine slot also channels one port to each of the Fabric Extenders. The result is 20 Gbps of bandwidth to each Fabric Extender. Figure 22 Option 3 - VIC 1240 and Emulex or QLogic I/O Adapter to UCS 2204XP Fabric Extender Cisco UCS B200 M3 Blade Server...
  • Page 61 Port A and B of the mezzanine adapter connect to the Fabric Extenders, providing 10 Gbps per port. Figure 24 Option 5 - Emulex or QLogic I/O Adapter to UCS 2204XP Fabric Extender (no VIC 1240 adapter) Cisco UCS B200 M3 Blade Server...
  • Page 62: Connectivity Using The Cisco Ucs 2104Xp Fabric Extender

    26, one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B. The result is 10 Gbps of bandwidth to each Fabric Extender. The Cisco Storage Accelerator adapter is located in the mezzanine connector as an independent device controlled by CPU 2.
  • Page 63: Technical Specifications

    Fully configured server ■ (2 HDDs, 2 CPUs, all memory, VIC 1240 and mezzanine adapter both populated) = 14.98 lbs (6.79 kg) Power Specifications For configuration-specific power specifications, use the Cisco UCS Power Calculator at: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Cisco UCS B200 M3 Blade Server...
  • Page 64 TECHNICAL SPECIFICATIONS Cisco UCS B200 M3 Blade Server...

Table of Contents