5) ELECTRICAL CONNECTION
The electrical connection must be done in
accordance with all electrical and installation
requirements of the Regulation.
Before proceeding with the connection, please,
verify that:
- The power of the electrical system and the power
of the outlets is adequate to the maximum power
of the appliance (see the identification label in the
lower part of the body).
- The electrical system must be earthed according
to
the
Regulations.
responsabilities for not observing such points.
- If the appliance is not equipped with an input
cable, connect to the clamp with an adequate
sized cable (see scheme paragraph 8) keeping
the "earth" conductor longer than "live" ones,
following the scheme of fig. 13-14.
When the connection to the input system has
been done through a outlet:
- Apply to the input cable "C", if unprovided, a
normalized plug adequate to the load indicated in
the identification label. Connect the cables
according to the scheme of fig.13-14, making sure
to respect the undermentioned respondences:
Letter L1 ( Live ) = cable red colour;
Letter L2 ( Neutral ) = cable black colour;
Symbol
( Ground ) = cable green - yellow
colour.
- The input cable has to be located so that it never
reaches a temperature over 75° C.
4 HEATING ELEMENTS
INSTALLATION
We
disclaim
FIG. 13
- Please do not use in the connection any
reduction, adaptation that may provoke a false
contact following dangerous overheatings.
- The outlet must be accessible after the built-in.
When the connection has been done directly to
the input system:
- Install between the appliance and the system an
omnipolar switch, adequate to the load of the
appliance, with a minimum nose between the
contacts of 3 mm.
all
- Keep in mind that the "earth" cable does not have
to be interrupted by the switch.
- In an alternative solution the electrical connection
can also be protected by a differential switch with
high sensitivity.
We recommend to fix the earth coloured cable to an
appropriate earth installation.
WARNINGS:
All our products are projected and built
according
EN 60 335-1 and EN 60 335-2-6 and relative
amendments.
The appliance has been produced according
with the European Directives:
- CEE 89/336 + 92/31 + 93/68 concerning the
compatibility electromagnetic.
- CEE 73/23 + 93/68 concerning the electrical
security.
2 HEATING ELEMENTS
8
to
the
European
FIG. 14
Norms

Advertisement