Flare Adjustment - Sony DXC-D35 Service Manual

Color video camera
Hide thumbs Also See for DXC-D35:
Table of Contents

Advertisement

3-3. Camera Adjustment
3. Adjust the lens iris to bring the white level "A" to 70
2 IRE.
Test point: VIDEO OUT connector
4. In the following items, by pressing the UP
DOWN
switches, adjust the waveform of the
oscilloscope to be flat.
GND: TP38/EX-490 board
Item
Test point
R W. SHAD
CL101
G W. SHAD
CL201
B W. SHAD
CL301
5. If the lens has an extender, set the extender ON and
perform the adjustment of step 4.
G
H
CL301
CL101
VA-169 board (B side) (DXC-D35/D35P)
VA-185 board (B side) (DXC-D35WS/D35WSP)
3-14
or
Specification
F
E
1
2
3
4
CL201
5
6

3-3-14. Flare Adjustment

Object:
Grayscale chart
Equipment:
Waveform monitor
Preparation:
. OUTPUT/DL/DCC + switch: CAM/DCC +
. Select a large lens iris and shoot the grayscale chart
covering fully the underscanned frame.
(Refer to Section 3-1-4.)
Test point:
VIDEO OUT connector
Adjustment Procedure
1. SERVICE menu "PAGE 3"
R FLARE: x
G FLARE: 5
B FLARE: x
n
Make sure that "G FLARE" is "5".
2. Push the WHT/BLK switch in the "BLK" direction to
make a black balance.
3. Adjust the lens iris to bring the white level to A = 100
IRE.
4. With the W. BAL switch set to "A", push the WHT/
BLK switch in the "WHT" direction to make a white
balance.
5. Make the lens iris large by two steps.
6. Adjust the flare with UP
alternatively to minimize the carrier leakage level.
and DOWN
switches
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxc-d35wsDxc-d35wspDxc-d35p

Table of Contents