Specifications - Honeywell GasAlert Extreme User Manual

Table of Contents

Advertisement

GasAlert Extreme
User Manual

Specifications

Instrument dimensions: 2.8 x 5.0 x 9.5 cm
(1.1 x 2.0 x 3.75 in.)
Weight: 82 g (2.9 oz.)
Operating temperature:
H
S, SO
, HCN: -40°C to +50°C (-40°F to +122°F)
2
2
CO: -30°C to +50°C (-22°F to +122°F)
NH
NH
(high range): -20°C to +40°C (-4°F to +104°F)
3,
3
Other gases: -20°C to +50°C (-4°F to +122°F)
Operating humidity:
CO, H
S, SO
, Cl
, HCN, NO
2
2
2
15% to 90% relative humidity (non-condensing)
Cl2: 10% to 95% relative humidity (non-condensing)
ClO2: 15% to 95% relative humidity (non-condensing)
O2: 0% to 99% relative humidity (non-condensing)
Detection range:
GasAlert Extreme O
: 0 – 30.0% vol. (0.1% vol. increments)
2
GasAlert Extreme CO: 0 – 1000 ppm (1 ppm increments)
GasAlert Extreme CO (low H
(1 ppm increments)
GasAlert Extreme H
S: 0 – 100 ppm (1 ppm increments)
2
GasAlert Extreme H
S (high range): 0 – 500 ppm (1 ppm increments)
2
GasAlert Extreme PH
: 0 – 5.0 ppm (0.1 ppm increments)
3
GasAlert Extreme SO
: 0 – 150.0 ppm (0.1 ppm increments)
2
GasAlert Extreme Cl
: 0 – 50.0 ppm (0.1 ppm increments)
2
GasAlert Extreme NH
: 0 – 100 ppm (1 ppm increments)
3
GasAlert Extreme NH
: (high range) 0 – 400 ppm (1 ppm increments)
3
GasAlert Extreme NO
: 0 – 100.0 ppm (0.1 ppm increments)
2
GasAlert Extreme HCN: 0 – 30.0 ppm (0.1 ppm increments)
50
, NH
, PH
, ETO, NO, O
:
2
3
3
3
sensitivity): 0 – 1000 ppm
2
GasAlert Extreme ETO: 0 – 100.0 ppm (0.1 ppm increments)
GasAlert Extreme ClO
: 0 – 1.00 ppm (0.01 ppm increments)
2
GasAlert Extreme O
: 0 – 1.00 ppm (0.01 ppm increments)
3
GasAlert Extreme NO: 0 – 250 ppm (1 ppm increments)
Sensor type: Plug-in electrochemical cells
Calibration: Auto zero, set span, and span sensor
Alarm conditions: TWA alarm, STEL alarm, low alarm, high alarm, sen-
sor alarm, low battery alarm, confidence beep, automatic shutdown
alarm.
Audible alarm: 95 dB at 0.3 m (1 ft.) typical
Visual alarm: Red light-emitting diode (LED)
Display: Alpha-numeric liquid crystal display (LCD)
Backlight: Automatically activates for 3 seconds whenever there is
insufficient light to view the display and during alarm conditions. Any
pushbutton reactivates the backlight for 6 seconds.
Self-test: Initiated upon activation
Battery test: Every 0.5 seconds
Battery: 3 V lithium Energizer 1CR2-series battery
Warranty: 2 years including sensors.
Approvals:
Classified by UL to both U.S. and Canadian Standards as Intrinsically
Safe for Class I, Division 1, Group A, B, C, D
European Explosives Protection EEx ia IIC
g
CE 0539
II 1 G DEMKO 04 ATEX 03 36363
IECEx
ABS Type Approved: VA-348-169-X