Upgrade Procedure

Verify that Prisma II chassis contains an ICIM2, and that the ICIM2's domain
1
contains the modules to be updated.
Set up the RS-232 interface to the ICIM2.
2
Note: this interface will be used to change and/or read settings such as IP
address, gateway address, subnet mask, etc.
3
Open a Hyperterm session and set up a COM port as follows:
Baud: 9600

No of data bits: 8

Parity: N
Stop bits: 1
Flow control: None
4
Connect an RS-232 cable from a COM port on the PC to the RS-232 port of the
ICIM2.
5
Press Enter and verify a response from the ICIM2. If no response, cycle power
on the ICIM2 and observe the Hyperterm display. The messages from the ICIM2
boot process should be visible.
6
Set up an FTP server. If an FTP server not available, refer to Setting Up FTP
Server Software on Your Local Computer (on page 11) for information about
installing and setting up an FTP server using Cerberus.
7
Add an account to the FTP server, specifying a username and a password.
Note: An account without a password will not work.
Install SOUP. If SOUP is not present on PC, install it. For general information,
8
refer to Prisma II XD Platform System Guide, System Release 2.03, part number
4025479. The revision being used in this procedure is 2.01.
Establish an IP connection with the ICIM2.
9
Obtain the ICIM2 IP address
1
Using the RS-232 interface and Hyperterm, log into the ICIM2 with a valid
username and password.
2
Type CLI and press Enter.
3
Type ICIM and press Enter.
Type SHOW IP and press Enter. The ICIM2 IP address will be shown.
4
78-4032387-01 Rev C