Installation Instructions - GE Monogram ZGU385N Installation Instructions Manual

36" stainless steel gas cooktops
Hide thumbs Also See for Monogram ZGU385N:
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
1_ INSTALL THE COOKTOP
A. Remove the screws on the sides of the cooktop
burner box. Use those screws to attach the side
mounting
brackets.
B. Insert the cooktop
centered into the cutout
opening. Make sure the front edge of the
countertop
is parallel to the cooktop.
Check clearances
at the front, back and sides.
Secure the hold-down
bracket to the cabinet
sides with screws.
[_
INSTALL PRESSURE REGULATOR
-AWA RN IN G: Never
reuse
old flexible
connectors.
The use of old flexible connectors
can
cause gas leaks and personal
injury.
Always
use
new flexible connectors
when installing
a gas
appliance.
To reduce the possibility
of gas leaks, apply teflon
tape or a thread compound
approved for use with
LP or Natural gases to all threaded
connections.
A. Screw the regulator
onto the burner box
bottom
pipe connection.
Make sure the top of
the regulator
is facing toward the cabinet front,
and the arrow on the back of the regulator
points to the cooktop.
To cool{top
regulator
Shut-off
valve
J
Rear view
of
regulator
(note
direction
of arrow)
Electrical outlet 12"
below countertop
B. Complete the connection
between the regulator
and the shut-off valve.
[_
INSTALL PRESSUREREGULATOR
(cont.)
C. Before testing for leaks, make sure all burner
knobs are in the OFF position.
After connecting
the cooktop to gas, check
system for leaks with a manometer.
If a manometer
is not available, turn the gas supply on to the
cooktop and use a liquid leak detector
at all
joints and connections
to check for leaks.
Tighten all connections
if necessary to prevent gas
leakage in the cooktop
or supply line.
WARN IN G: Do not
u se a
flame to
check for leaks.
Disconnect
the cooktop
and its individual
shut-off
valve from the gas supply piping system during any
pressure testing of that system at test pressures
greater than 1/2 psig (3,5 kPa),
Isolate the cooktop
from the gas supply piping
system by closing its individual
shut-off valve during
any pressure testing of the gas supply system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
[3]
CONNECT ELECTRICAL
• Check to be sure the receptacle
is properlg
grounded.
• Plug in the power cord.

Advertisement