Tools You Will Need; Adjusting The Regulator; Changing The Orifices - GE Monogram ZGU385N Installation Instructions Manual

36" stainless steel gas cooktops
Hide thumbs Also See for Monogram ZGU385N:
Table of Contents

Advertisement

Available languages

Available languages

J Ilnstallat.ion
nstructlons I
Convert Natural Gas Model ZGU385NSMSS
to LP Gas Operation
SAFETY INFORMATION
The pressure regulator and burner orifices are set for
natural gas operation.
To convert this cooktop from natural gas operation to
LP operation, the regulator and burner orifices must be
converted. LP burner orifices are attached to the regulator.
CAUTION
- The cooktop, as shipped from the
factorg, is set for use with its intended gas. If gou wish
to use gour cooktop with the alternate gas, gou must
first replace the orifices and convert the pressure
regulator.
-_ WARNING- This conversion
must be
performed bg a qualified installer or gas supplier in
accordance with the manufacturer's instructions and
all codes and requirements of the authoritg having
jurisdiction. Failure to follow instructions could result in
serious injurg or propertg damage. The qualified agencg
performing this work assumes responsibilitg for the
conversion.
CAUTI 0 N - The
following adjustments
must
be made before turning on the burner. Failure to do so
could result in serious injurg. Be sure pressure regulator
has been converted as described in Step 1.
TOOLS YOU WILL NEED FOR
CONVERSION
Crescent
wrench
7mm
nutdriver
Safety
glasses
Small
flat-head
screwdriver
(2 to 2.4 mm or
3/32" tip size,
60 mm long)
_]
ADJUST THE REGULATOR
A, Disconnect all electrical power, at the main circuit
breaker or fuse box.
& Shut offthe gas supply to the cooktop by closing the
manual shut-off valve.
C. Adjust the pressure regulator by the following
instructions:
• Unscrew the cap.
• Place your thumb against the flat side of the spring
retainer and press down to remove the retainer.
• Carefully look at the spring retainer to locate the NAT
or LP position.
Cap
Gasket
__/_
Spring
NAT _**[--_""
""_L p_p rroe;:in; r
position
_ _ ..........................
:_'..L position
Pressure regulator
• Turn the spring retainer over so that the desired gas is
showing on the bottom.
• Snap the retainer back into position,
• Screw the cap back onto the regulator.
15
J_
CHANGE BURNER ORIFICES
INSTALLATION TIP: Firstremove all
Burner cap
orifices and then start replacing them.
This will help to prevent the possibility
that some may not be replaced.
Burner ._
A. Removethe burner grates,
(_
burner caps and burner heads,
head
8. Using a 7mm nut driver,remove the
top burner orifices.There are two
orifices per burner.
The main orifice is
located low in the center
of the burner,while the
simmer orifice is located
higher besidethe center
of the burner.
_er
Spark igniter
base
Simmer
orifice.
__
Main
__
orifice

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zgu385l

Table of Contents