Honeywell Galaxy 3-48C Installation Manual page 13

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Installation Manual
NOTE:
*
Valid addresses for the
keyprox are:
Line 1 (0, 1 & 2).
Lines 2, 3 & 4 (0-6).
This sets the address for both
the keypad and card reader
parts of the keyprox.
*
Certain keypad and
max addresses can
be replaced by a
combined keyprox unit.
NOTE:
RIOs, RF RIO's and
PSU's can be mixed on
the lines. The maximum
number of combined
modules is given in the
table below.
NOTE: Each Output Module can simulate
up to 4 RIO's (outputs only) depending
on DIP switch setting.
Valid addresses for the Output Module are
the same as standard RIO's.
NOTE:
The Telecom, Printer Interface,
RS232, Ethernet and ISDN
modules can only be
connected to line 1.
If a Telecom module is attached,
keypad address E cannot be
connected to line 1(address E is
shown as 18 on the system).
If an RS232 module is attached,
keypad address D cannot be
connected to line 1 (address D is
shown as 17 on the system).
If an Ethernet module is attached,
keypad address B cannot be
connected to line 1 (address B is
shown as 15 on the system).
If an ISDN module is attached,
keypad address C cannot be
connected to line 1 (address C is
shown as 16 on the system).
On-board
Galaxy Panel
Zones
Outputs
520 (line 1)
16
8
(lines 2, 3, 4)
PSTN
RS232
Serial Port
Cable run 1 km (max)
Keypads (8)
*
CP027/
Keyprox (3)
CP028
*
Max (8)
MX03
4 outputs
RIO (15)
C072
8 zones
OR
4 outputs
Smart PSU (15)
P015
8 zones
OR
4 outputs
Power Unit (15) P025
or
Power RIO (15) P026
8 zones
OR
RF RIO Module (15)
C076
Output Module (4) C078
4 - 16 outputs
Telecom Module (1)
E062 (comm 5)
RS232 Module (1)
E054 (comm 2)
ISDN Module (1)
E077 (comm 3)
Ethernet Module (1)
E080 (comm 4)
Printer Interface (1)
A134/A161
RIOs/ Smart PSUs/EN51 PSU
Poss.
Address
Zones
15
1 - 9, A - F
120
16
0 - 9, A - F
384
Figure 2-3. Galaxy 3-520 System Configuration
G3-520 Configuration
16 zones on board
on board
8 outputs
telecom
Galaxy 3-520
on board
area
Line
Line
Line
Line
1
2
3
4
Lines 2, 3 and 4 have the same configuration
Cable run 1 km (max)
*
Keypads (8)
CP027/
Keyprox (7)
CP028
*
Max (8)
MX03
4 outputs
8 zones
4 outputs
8 zones
4 outputs
Twisted Pair
Screened Cable
8 zones
W002
4 - 16 outputs
Keypads
Outputs
Poss.
Address
60
8
0 - 2, B, C, D, E, F
64
8
0 - 6, F
2-3
RIO (16)
C072
OR
Smart PSU (16)
P015
OR
Power Unit (16) P025
or
Power RIO (16) P026
OR
RF RIO Module (16)
C076
Output Module (4)
C078
Keyprox
Poss.
Address
3
0-2
7
0-6
MAX
Poss.
8
8

Hide quick links: