Honeywell Galaxy 3-48C Installation Manual page 12

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

G3-144 Configuration
PSTN
(comm 1)
RS232
Serial Port
(comm 6)
NOTE:
RIOs, RF RIO's and
PSU's can be mixed on
the lines. The maximum
number of combined
modules is given in the
table below.
NOTE: Each Output Module can simulate
up to 4 RIO's (outputs only) depending
on DIP switch setting.
Valid addresses for the Output Module are
the same as standard RIO's.
NOTE:
The Telecom, Printer Interface,
RS232, Ethernet and ISDN
modules can only be
connected to line 1.
If a Telecom module is attached,
keypad address E cannot be
connected to line 1(address E is
shown as 18 on the system).
If an RS232 module is attached,
keypad address D cannot be
connected to line 1 (address D is
shown as 17 on the system).
If an Ethernet module is attached,
keypad address B cannot be
connected to line 1 (address B is
shown as 15 on the system).
If an ISDN module is attached,
keypad address C cannot be
connected to line 1 (address C is
shown as 16 on the system).
On-board
Galaxy Panel
Zones
Outputs
144 (line 1)
16
8
(line 2)
16 zones on board
on board
8 outputs
telecom
Galaxy 3-144
on board
area
Line
Line
1
2
Cable run 1 km (max)
NOTE:
Keypads (8)
*
CP027/
Valid addresses for the
*
Keyprox (3)
keyprox are:
CP028
Line 1 (0, 1 & 2).
Line 2 (0, 1, 2, & 3 ).
This sets the address for both
the keypad and card reader
parts of the keyprox.
*
Certain keypad and
max addresses can
be replaced by a
RIO (8)
combined keyprox unit.
C072
OR
4 outputs
Smart PSU (8)
P015
OR
4 outputs
Power Unit (8) P025
or
Power RIO (8) P026
8 zones
OR
RF RIO Module (8)
C076
Output Module (4) C078
4 - 16 outputs
Telecom Module (1)
E062 (comm 5)
RS232 Module (1)
E054 (comm 2)
ISDN Module (1)
E077 (comm 3)
Ethernet Module (1)
E080 (comm 4)
Printer Interface (1)
A134/A161
RIOs/ Smart PSUs/EN51 PSU
Poss.
Address
Zones
8
1 - 8
64
8
0 - 7
64
Figure 2-2. Galaxy 3-144 System Configuration
Galaxy 3 Series Installation Manual
*
Max (4)
MX03
4 outputs
8 zones
*
8 zones
Twisted Pair
Screened Cable
W002
Keypads
Outputs
Poss.
32
8
0 - 2, B, C, D, E, F
32
8
0 - 6, F
2-2
*
Keypads (8)
CP027/
Keyprox (4)
CP028
Max (4)
MX03
4 outputs
RIO (8)
C072
8 zones
OR
4 outputs
Smart PSU (8)
P015
8 zones
OR
4 outputs
Power Unit (8) P025
or
Power RIO (8) P026
8 zones
OR
RF RIO Module (8)
C076
4 - 16 outputs
Output Module (4)
C078
Keyprox
Address
Poss.
3
0-2
4
0-3
MAX
Address
Poss.
4
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: